19
Setting the OFF time
1. Press CLOCK to access the timer function.
2. When the indicator light is on and the time is flashing,
press CLOCK again to set the hour. Use UP
or DOWN to adjust.
3. While the display is still flashing, press to set
minute. Use UP or DOWN to adjust.
4. After adjustment, press TIMER OFF to confirm
the setting, and the water temperature will be
displayed. After 30 seconds, the display will revert to
its default mode.
Canceling automatic mode
1. Press TIMER ON or TIMER OFF to cancel
automatic on/off operation.
2. While the LED is still flashing, press CLOCK .
Note that when the timer indicator light goes off, and
LED shows water temperature, the timer automatic
on/off function is canceled.
After 30 seconds, the display will revert to its default mode.
Defrosting
NOTE: Manual defrosting intervals should be more than
30 minutes and the compressor should run for more
than 10 minutes.
7. OPERATING INSTRUCTIONS
Start-Up Procedures
Figure 14. Heater Control - Inverter Models Only
TIMER ON
MODE
TIMER INDICATOR
LIGHT
TIMER
INDICATOR
LIGHT
POWER ON/OFF
TIMER OFF
WATER TEMP
AND
TIME SETTING
CLOCK
Heat
Cool
Figure 15. Heater Control - On/O󰀨 Models Only
If your heater has been installed correctly, operating the
heater is an easy task. The display allows you to turn the
heater ON or OFF and adjust the temperature settings for
the pool or spa. The temperature range is factory-set from
64°F (18°C) to 104°F (40°C) - HEAT ONLY. 54°F (12°C) to
86°F (30°C) - COOL ONLY.
Details on Inverter Models for starting, and adjusting the
settings, see page 17. For On/O󰀨 Models see page
18.
Before Start-Up
Model Identication
The model number of the heater can be found on the rating
plate, Figure 1.
Water
Water must be owing through the heater during operation.
Ensure that the system is lled with water and that the
pump is operating.
AA
WARNING: Operation of the heater without water
circulation will cause rapid and severe damage to the
heater, and will void the warranty.
Starting
NOTE: The user must start the pool pump before the
heater, and turn o󰀨 the heater before the pool pump, or
the heater will be damaged.
The user should start the pool pump, and check for any
leakage of water; Power on and press the ON/OFF button
on the heater, and set a suitable temperature at the
thermostat.
In order to protect the heater, the heater is equipped with a
time-delay starting function. When starting the heater, the
blower will run for 1 minute before the compressor.
After the heater starts up, check for any abnormal noise
from the heater.
After Start-Up
Feel the inlet and outlet pipes. Outlet pipe should be only
slightly warmer than the inlet. It should not be hot.
Details on Inverter Models for adjusting the settings see
page 17. For On/O󰀨 Models see page 18.
6100.64_Crosswind.indd 19 11/26/2019 4:16:49 PM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raypak CROSSWIND Series and is the answer not in the manual?

Raypak CROSSWIND Series Specifications

General IconGeneral
CategorySwimming Pool Heater
BrandRaypak
Fuel TypeNatural Gas or Propane
SeriesCROSSWIND
Water Flow Rate20 - 120 GPM
Warranty5 years