RCF spa
M 20X Digital Mixer Reference Guide
27
PEQ8 Operating Modes
PEQ parameters assigned to the Encoders are:
BAND SELECT: this parameter allows to select the single filter band
FREQ: set the value of Frequency of the selected band in the range [20: 20k] Hz
GAIN: set the value of Gain of the selected band in the range [-12: 12] dB
TYPE/Q: this parameter change according to the selected filter band:
Band1
o Low SHELF Filter type
o High Pass 12 dB/oct Filter type
o High Pass 24 dB/oct Filter type Band1 combined with Band2
o Peaking Filter Q parameter in the range [1: 20]
Band2, Band3, Band4, Band5, Band6, Band7
o Peaking Filter Q parameter in the range [1: 20]
Band8
o High SHELF Filter type
o Low Pass 12 dB/oct Filter type
o Low Pass 24 dB/oct Filter type Band7 combined with Band8
o Peaking Filter Q parameter in the range [1: 20]