Table 3: Inspection and Maintenance Recommendations
(NOTE: RML website www.reflexmarine.com/support should be checked for the latest version of this table)
INSPECTION AND
MAINTENANCE
RECOMMENDATIONS
(FROG-3 & FROG-6
TRANSFER PRODUCTS)
Rev 03 - 120501
RECOMMENDED FREQUENCY
INSPECTIONS
LOAD TESTS
MAINTENANCE
Pre
Operational
Visual Check
Visual
Inspection
Examination
Post Load
Test Visual
Inspection
Proof Load Test
Sling
Replacement
Critical Parts
Replacement
Unit
Replacement
USAGE CATEGORY
Section 6.4
Section 6.5
Section 6.6
Section 6.7
Section 6.8
Section 6.9
Section 6.10
Section 6.11
Usage
Category
No of
Transfer Lifts
per year
not exceeding
not exceeding
(depending on Visual
Inspection) this period
may be reduced
not exceeding
not exceeding
not exceeding
Very Low
<20
before every
use
6 months
12 months
After Load
Test
On Critical Parts
Replacement
12 months
36 months
10* years
Low
<100
before every
use
6 months
12 months
After Load
Test
On Critical Parts
Replacement
12 months
36 months
8 years
Medium
100 to 500
before every
use
6 months
12 months
After Load
Test
On Critical Parts
Replacement
12 months
24 months
7 years
High
500 to 1500
before every
use
3 months
12 months
After Load
Test
On Critical Parts
Replacement
6 months
12 months
6 years
Very High
1500 to 2500
before every
use
3 months
12 months
After Load
Test
On Critical Parts
Replacement
3 months
12 months
4 years
Ultra High
2500 to 5000
before every
use
3 months
6 months
After Load
Test
On Critical Parts
Replacement
3 months
6 months
3 years
*This may be extended subject to a ‘condition & service assessment’ carried out by RML (Reflex Marine Ltd) or an ASC (Accredited Service Centre).