INSTALLATION
When installing the optional Tripoli Arch Door, a non-combustible material 12" (305mm) above the unit and 6" (153mm) on each side must be used. See
diagram 2. For complete framing dimensions - see instructions in this manual.
The Tripoli Arch Door also requires steel stud framing above and on each side of the unit, see diagram 2.
TRIPOLI ARCH DOOR FRAMING NOTE
Steel
Stud
Steel
Stud
Min. 12"
(305mm)
Min. 6"
(153mm)
Min. 6"
(153mm)
P36
36-1/4"
(921mm)
36-1/4"
(921mm)
Non - Combustible
Material
27-1/2”
(699mm)
30 -7/8”
(784mm)
P36D
376-1/4"
(946mm)
Diagram 1
Front Framing Dimensions using the
Regency Tripoli Screen Door Option