PH10 PLUS installation and user's guide
Documentation part number: H-1000-7592-03-C
PH10 PLUS installation and user's guide
www.renishaw.com
Issued 03 2020
1

Questions and Answers

  • M
    meredithrobertsAug 3, 2025
    Why are my Renishaw Measuring Instruments showing poor measurement performance?
    • Z
      Zachary KirkAug 3, 2025
      If you are experiencing poor measurement performance with your Renishaw Measuring Instruments, there are several potential causes. First, ensure that all mounting screws are tight and that the mounting to the CMM is secure, as a loose head mounting can cause this issue. Also, remove and reattach the probe to ensure it is correctly attached. Another cause could be force applied to the head during lock up, so try locking and unlocking the head. Also, check the qualification information, as the position might not be qualified. Finally, make sure that the head is correctly positioned.
  • Q
    qwarrenAug 8, 2025
    What causes a datum error in Renishaw Measuring Instruments?
    • M
      Mr. Kevin DeanAug 8, 2025
      If your Renishaw Measuring Instruments experience a datum error, it could be due to faulty cables or connections. Check the condition of the cabling from the head to the controller. Alternatively, the head/stylus configuration may be obstructed; remove any obstructions and update the head using HCU1 or under CMM control. Another potential cause is a probe extension combination that is too long; try using a shorter/lighter stylus combination.
  • J
    Jacob CunninghamAug 13, 2025
    What to do if Renishaw Measuring Instruments show an overload error?
    • L
      lisawilliamsonAug 13, 2025
      If your Renishaw Measuring Instruments display an overload error, it could be due to the head lock-up holding force being exceeded during CMM acceleration. To resolve this, try reducing the mass of the probe combination or decreasing the acceleration. Alternatively, the error might be caused by a collision with the workpiece or CMM. In this case, inspect the head for damage, remove any obstructions, and then repeat the move.
  • M
    Monica CastilloAug 18, 2025
    What to do if Renishaw Measuring Instruments have no probe signal?
    • D
      Danny CainAug 18, 2025
      If your Renishaw Measuring Instruments are showing a 'No probe signal' error, start by checking if the probe is correctly attached. Remove it and then reattach it securely. You should also check the condition of the cabling from the head to the controller, as faulty cables or connections can cause this issue. If these steps don't resolve the problem, there may be an issue with the probe output being disabled by the CMM. Check the probe output to ensure it is enabled.
  • M
    Matthew WilliamsAug 25, 2025
    Why do Renishaw PH10 PLUS Measuring Instruments show an obstruct error?
    • A
      Andrea FosterAug 25, 2025
      If your Renishaw Measuring Instruments are showing an obstruct error, it could be due to several reasons. * First, check the head for damage and remove any obstructions before repeating the move, as the head/stylus configuration might be obstructed. * It's also possible that the probe extension combination is too long; try using a shorter or lighter stylus combination.
  • P
    Paul BennettAug 28, 2025
    How to troubleshoot no head movement in Renishaw Measuring Instruments?
    • D
      darryl32Aug 28, 2025
      If there is no head movement in your Renishaw Measuring Instruments, it could be due to a power loss. Check that the controller power LED is lit, inspect the mains cable for its condition and integrity, check the controller fuse, and verify the emergency stop condition. Another possible cause is faulty cabling or connections. Check the condition of the cabling from the head to the controller.

Summary

International Safety Instructions

Multilingual Safety Warnings

Safety warnings in multiple languages as per international standards.

General Warnings

General Safety Advice

Important safety advice and precautions for using the equipment.

PH10 System Description

System Interconnection Diagrams

PH10 Compatible Probes

PH10 Connection of Probes and Extensions

System Diagrams

HCU2 Hand Control Unit

PHC10-3 PLUS Probe Head Controller

Powering the PHC10-3 PLUS

Information on powering the PHC10-3 PLUS controller.

PHC10-3 PLUS Rear Panel Layout

Description of the PHC10-3 PLUS controller's rear panel connections.

PHC10-3 PLUS LED Description

Explanation of the LED indicators on the PHC10-3 PLUS controller.

PHC10-3 PLUS Variants

Overview of the different available versions of the PHC10-3 PLUS controller.

Specifications

PH10 PLUS Range Dimensions

Operating Modes

Manual Mode Operation

Using the HCU2 for manual control of the probe head.

Automatic Mode Operation

System operation under CMM computer control.

Maintenance and Troubleshooting

Troubleshooting Common Errors

Diagnosing and resolving common errors like overload or obstruction.

Troubleshooting Signal and Performance Issues

Resolving issues related to probe signals and measurement performance.

Renishaw PH10 PLUS Series Specifications

General IconGeneral
BrandRenishaw
ModelPH10 PLUS Series
CategoryMeasuring Instruments
LanguageEnglish