23
Menu Options
Basic Settings – Charge
Cell Type – specifies the type of cell for that battery chemistry. In Lead Acid packs, the charge
end voltage for SLA/Gel cell is fixed at 2.40V/cell and the charge end voltage for AGM cell is
fixed at 2.45V/cell.
Charge Amps – sets the charge current. The charge current is used for the constant current
portion of the charge.
Chg V/cell – sets the desired cell voltage for Lithium packs. This value can be reduced to under
charge a pack, or raised to over charge a pack.
No of Cells – Cells can be auto or fixed. If the cell count is fixed, only packs that verify this count
can be charged.
Basic Settings – Discharge
Cell Type – specifies the type of cell for that battery chemistry.
Discharge Amps – sets the discharge current (or regenerative discharge current if the Regen
Discharge option is On).
Disch V/cell – sets when to stop the discharge.
No of Cells – Cells can be auto or fixed. If the cell count is fixed, only packs that verify this count
can be discharged.
Basic Settings - Store
Cell Type – specifies the type of cell for that battery chemistry.
Charge Amps – sets the charge current. The charge current is used for the constant current
portion of the charge.
Discharge Amps – sets the discharge current (or regenerative discharge current if the Regen
Discharge option is On).
Store V/Cell – specifies the cell voltage to charge/discharge to.
Basic Settings - Cycle
Cell Type – specifies the type of cell for that battery chemistry.
Charge Amps – sets the charge current. The charge current is used for the constant current
portion of the charge.
Discharge Amps – sets the discharge current (or regenerative discharge current if the Regen
Discharge option is On).
Chg V/cell – sets the desired cell voltage for Lithium packs. This value can be reduced to under
charge a pack, or raised to over charge a pack.
Disch V/cell – sets when to stop the discharge.
No of Cells – Cells can be auto or fixed. If the cell count is fixed, only packs that verify this count
can be discharged.
Basic Settings - Monitor
Cell Type – specifies the type of cell for that battery chemistry.