Menu Options
Basic Settings Charge
Cell Type specifies the type of cell for that battery chemistry. In Lead Acid packs, the charge
end voltage for SLA/Gel cell is fixed at 2.40V/cell and the charge end voltage for AGM cell is
fixed at 2.45V/cell.
Charge Amps sets the charge current. The charge current is used for the constant current
portion of the charge.
Chg V/cell sets the desired cell voltage for Lithium packs. This value can be reduced to under
charge a pack, or raised to over charge a pack.
No of Cells Cells can be auto or fixed. If the cell count is fixed, only packs that verify this count
can be charged.
Basic Settings Discharge
Cell Type specifies the type of cell for that battery chemistry.
Discharge Amps sets the discharge current (or regenerative discharge current if the Regen
Discharge option is On).
Disch V/cell sets when to stop the discharge.
No of Cells Cells can be auto or fixed. If the cell count is fixed, only packs that verify this count
can be discharged.
Basic Settings - Store
Cell Type specifies the type of cell for that battery chemistry.
Charge Amps sets the charge current. The charge current is used for the constant current
portion of the charge.
Discharge Amps sets the discharge current (or regenerative discharge current if the Regen
Discharge option is On).
Store V/Cell specifies the cell voltage to charge/discharge to.
Basic Settings - Cycle
Cell Type specifies the type of cell for that battery chemistry.
Charge Amps sets the charge current. The charge current is used for the constant current
portion of the charge.
Discharge Amps sets the discharge current (or regenerative discharge current if the Regen
Discharge option is On).
Chg V/cell sets the desired cell voltage for Lithium packs. This value can be reduced to under
charge a pack, or raised to over charge a pack.
Disch V/cell sets when to stop the discharge.
No of Cells Cells can be auto or fixed. If the cell count is fixed, only packs that verify this count
can be discharged.
Basic Settings - Monitor
Cell Type specifies the type of cell for that battery chemistry.