SC015
Supply V Exceed
Regen V Max
Switching To
Internal Discharge
During regenerative discharge, the supply voltage has reached the Regen V.
Max. option setting.
SC019
Cannot
Load an
Empty Preset
Attempting to load a blank/empty User Preset.
SC020
Bad Cell Count
Check Wiring
Check the balance connector or adapter.
Check the main discharge connectors.
SC024
Maximum Charge
Amps Exceeded
Check the wiring for a loose connection. Check the supply wiring too.
SC025
Maximum Discharge
Amps Exceeded
Check the wiring for a loose connection. Check the supply wiring too.
SC026
Supply Voltage
Above High
Voltage Limit
Supply voltage is too high.
SC027
Supply Voltage
Below Low
Voltage Limit
Supply voltage is too low.
SC028
Unstable Amps
Check Wiring
Check the wiring for a loose connection. Check the supply wiring too.
SC030
Mains Lead
Reversed
Check the battery pack to charger connections. Battery positive connects to
charger red terminal and battery negative connects to charger black terminal.
SC032
Battery Voltage
Too High
Check the main discharge connectors for a loose connection.
SC035
Charge Capacity
Limit Exceeded
The charge capacity has reached the Chg Cap Limit option setting.
SC036
Discharge Capacity
Limit Exceeded
The discharge capacity has reached the Disch Cap Limit option setting.
SC037
Charge Timeout
Exceeded
The charge time elapsed has reached the Chg Timeout option setting.
SC038
Discharge Timeout
Exceeded
The discharge time elapsed has reached the Disch Timeout option setting.