SC039
Batt & Cell Sum
Does Not Add Up
Check Wiring
Check the balance connector or adapter.
SC040
Internal Temperature
Limit Exceeded
High internal temperature warning. Check fan operation.
SC041
Pack Below 3.0V
Use Regen Discharge
The pack voltage is too low for an internal discharge operation.
SC042
Cell Volts Diff
High
Chg Amp Reduced
Safety charge activated due to cell volts range too high.
SC043
Input Amp
Limit Reached
Chg Amp Reduced
Supply amps has reached or exceeded the Smart Power Management setting.
The cell voltage is out of range.
The cell voltage is out of range.
Check supply connections. Do not attempt a regenerative discharge into a DC
power supply.
SC048
Code Checksum Bad
Return Charger to
Factory
Firmware is corrupted. Try updating firmware again.
SC049
Calibration Checksum
Bad Return Charger
to Factory
Calibration parameters are corrupted.
SC050
Int Temp High
Chg Amp Reduced
Operate charger in a well ventilated environment and ensure air flow behind fans
is not obstructed. Do not place the charger on a hot surface eg. an external power
supply.
SC051
Int Temp High
Rgn Amp Reduced
Operate charger in a well ventilated environment and ensure air flow behind fans
is not obstructed. Do not place the charger on a hot surface eg. an external power
supply.