8
Regenerative Discharge
Regenerative discharge routes most of the energy from the pack being discharged back
into the Lead Acid battery powering the GT1000. This feature is only available when the
GT1000 is powered from a Lead Acid battery. Regenerative discharge supports up to
40A, 1000W maximum.
Regenerative discharge
Enable/disable regenerative discharge at the GT1000 via Smart Power Management
for the supply battery.
GT1000 automatically determines whether it is connected to a Lead Acid battery or a DC
power supply. If it detects a power supply, it switches to internal discharge (10mA to 8A,