No of Cells allows cells from 2s to 6s to be Unbalanced Discharge. Only packs that verify this
count can be discharged.
Settings - Supply Settings
Power Source specifies the input source for Smart Power Management. The GT1000 stores
six Smart Power Management profiles: three for DC power supplies (PSU1, PSU2, PSU3) and
three for Lead Acid batteries (Batt1, Batt2, Batt3). After changing the settings in any of the six
profiles, remember to use the Power Source option to load the correct Smart Power
Management profile for the input source you’re currently using.
Low Volt Limit specifies the cutoff voltage. (Cutoff voltage should be about 50% lower than
the power supply’s nominal output voltage. Example: For a 24V power supply, set the cutoff
voltage to 12V. To protect your power supply, charging reduces or stops if the power supply’s
voltage drops below the value you set here.)
Current Limit specifies the current limit appropriate for your DC power supply or Lead Acid
battery. (Maximum output current capability of Lead Acid batteries varies widely. Generally, a
standard flooded Lead Acid car battery might deliver 25A continuously and 50A for short periods.
An AGM style might not have any trouble delivering 50A continuously without suffering
substantially shortened life. To protect your battery from damage, GT1000 will never draw more
current than you specify here, but charge current may not reach the preset or manually set
value.)
Regen Discharge enables regenerative discharge mode. (Regenerative discharge puts
energy back into a battery power source during pack discharge cycles.)
Regen V. Max limits the voltage at the power source during regenerative discharge by
reducing the regenerative discharge amp when this voltage has been reached or exceeded. It
is recommended to check your Lead Acid battery power source specifications to determine the
correct maximum voltage to set.
Regen A. In Max specifies the maximum current flowing into the Lead Acid battery power
source during regenerative discharge.
Pwr On Default specifies the default power source each time the charger is powered on. If
one of the six power supply profiles is selected, the SELECT POWER SUPPLY menu will not
appear at startup for you to select a power source. If you would like to have the option to choose
a power source each time during startup, leave the Pwr On Default option at Select.
Settings - Audio Settings
Speaker Volume sets the loudness (Off, 1 = quietest, Max = loudest).
Finish Beeps controls how many times the GT1000 repeats “beep beep beep” when charging
is complete.
Button Beep enables or disables the speaker beep” when the ENTER or BACK button is
pressed. This option is not applicable if the Speaker Volume option is Off.
Settings - Visual Settings
Info Scroll Time during Charge/Discharge/Regen/Monitor, enables auto-scrolling of battery
pack and supply status information and by setting the time delay between different screens (Off
= turn off auto-scrolling).
Menu Dir Inv sets the direction of movement of the highlighted item during menu navigation
(Off = scrolls the highlighted item down when the navigation wheel is turned anti-clockwise, On
= scrolls the highlighted item down when the navigation wheel is turned clockwise)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Revolectrix GT1000 and is the answer not in the manual?

Revolectrix GT1000 Specifications

General IconGeneral
BrandRevolectrix
ModelGT1000
CategoryBattery Charger
LanguageEnglish

Related product manuals