EasyManuals Logo

Revolectrix GT1000 User Manual

Revolectrix GT1000
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
9
Power supplies
GT1000 is one of the highest power RC battery maintenance devices available. Running
full power, it can deliver 1000W to batteries during charge. To achieve this, even on a 6
cell Lithium battery, it must boost the input voltage. This means the GT1000 may draw
up to 1200W from the input power supply.
To take advantage of GT1000’s full power capability, the power source should be 30V
DC (higher voltage does not improve output power), and capable of delivering a
minimum of 40A to GT1000’s input.
If you don’t need GT1000’s full output power, it can operate from much lower power
sources. Use the steps outlined in Example 1: Configuring Smart Power Management to
configure GT1000 to never exceed the maximum capabilities of your input source(s),
whether DC power supply or Lead Acid battery.
Important: Unstable power supplies can damage the charger. To help
reduce risk to the charger observe the following:
1) When powering more than one Charger/Battery Workstation from the
same supply, ensure that all connected chargers are idle (not charging)
when connecting the second or third charger. Alternatively, connect all
chargers to the supply before the supply is powered up.
2) When powering the Charger/Battery Workstation from an automotive
battery (Lead Acid) installed in a vehicle, do not start or stop the vehicle’s
engine unless the charger is idle, or disconnected from the automotive
battery (Lead Acid).
3) When powering any Revolectrix Charger or Battery Workstation using
the E-Fuel 1200W/50A power supply:
i) first connect the Power Supply to AC power BEFORE connecting the
charger to the Power Supply.
ii) set the voltage on the Power Supply so it is within the operating range
of the Charger or Battery Workstation you will be powering.
iii) wait at least 15 seconds.
iv) then connect the Charger or Battery Workstation to the Power
Supply.
v) conversely, disconnect the Charger or Battery Workstation from the
Power Supply BEFORE disconnecting the Power Supply from AC
power.