Message Causes Solutions
"Cannot write on the memory
storage device because
remaining free space is
insufficient."
The memory device is full and
scan data cannot be saved.
Even if the memory device
appears to have sufficient
free space, data might not be
saved if the maximum number
of files that can be saved is
exceeded.
• Replace the memory device.
• If the document is scanned as
single-page or divided multiple
pages, data already written to the
memory device is saved as is.
Replace the memory device, and
then press [Retry] to save the
remaining data, or press [Cancel]
to redo the scan.
"Cannot write on the memory
storage device because the
device is write-protected."
The memory device is write-
protected.
Unlock the write-protection on the
memory device.
"Captured file exceeded
max. number of pages per
file. Cannot
send the scanned
data."
The maximum number of
pages per file has been
exceeded.
Reduce the number of pages in the
transmitted file,
and then resend the file.
See "Storage function", Scanner
Reference
.
"Connection with LDAP server
has failed. Check the server
status."
A network error has occurred
and connection has failed.
Try the operation once more.
• Try the operation once more. If the
message
is still shown, the network
may be crowded.
• In [System Settings], under
[Administrator Tools], check the
settings of LDAP server. For details,
see "Programming the LDAP
server", Network and System
Settings Reference
.
"Connection with the
destination has failed. Check
the status and connection. To
check the
current status, press
[Scanned Files Status]."
The correct Network settings
are not made.
• Check the network settings of the
client computer.
• Check that
components such as the
LAN cable are connected
properly.
• Check that the server settings are
correct and the server is working
properly.
Messages Displayed When Using the Scanner Function
63