876-1
Log data error 1
An error was detected in the handling of the log data at power on or
during machine operation. This can be caused by switching the machine
off while it is operating.
• Initialize the HDD with SP5832-4
876-2
Log data error 2
HDD encryption unit not installed.
• Install the HDD encryption unit.
876-3
Log data error 3
Invalid log encryption key due to defective NVRAM data.
• Initialize the HDD with SP5832-4
•
Request customer's system administrator to disable HDD encryption
with the User Tool.
876-4
Log data error 4
Erratic HDD encryption due to defective NVRAM data.
• Initialize HDD with SP5832-4
876-5
Log data error 5
• Re-install the previous NVRAM or HDD.
•
Initialize the HDD with SP5832-4.
876-99
Log data error 6
An error other than Log Data Errors 1 to 5 occurred.
• Request assistance from your supervisor.
877
B
Security SD card error CTL
An error occurred, preventing successful execution of the Data Overwrite Security function,
even though it has been set up and enabled.