2. TECHNICAL DATA
2.1 TECHNICAL DATA
For gas family 3 (LPG) ask for separate kit.
2.2 OVERALL DIMENSIONS
2.3 WORKING FIELD (as EN 676)
Thermal power (1) 42 – 116 kW - 36,000 – 100,000 kcal/h
Natural gas (Family 2)
Net heat value: 8 – 12 kWh/Nm
3
- 7,000 – 10,340 kcal/Nm
3
Pressure: min. 16 mbar - max. 100 mbar
Electrical supply Single phase, 230V
± 10%
~
50Hz
Motor 230V / 0.7A
Capacitor 4 F
Ignition transformer
Primary 230V / 1.8A - Secondary 8 kV / 30 mA
Absorbed electrical power 0.13 kW
(1) Reference conditions:
Temp. 20°C - Barometric pressure 1013 mbar – Altitude 0 m above sea level.
COUNTRY DE AT FR ES - GB- IE LU NL
GAS CATEGORY
II
2ELL3B/P
II
2H3B/P
II
2Er3P
II
2H3P
II
2E3B/P
II
2L3B/P
O
Combustion head extension, supplied separately.
FlangeBurner
305 110 346 185
33 61
4
5
°
ø
105
262
160
Rp 3/4
204
142
O
170
D4251
130
11
4
5
°
Thermal power
D5256
0.8
0
0.2
0.4
0.6
40,000 50,000 60,000 70,000
kcal/h
1206050 70 80 kW
1.0
110
80,000
1.2
90 100
90,000
1.4
40
1.6
100,000
Pressure in the combustion
chamber – mbar