EasyManua.ls Logo

Riello NXHM - How to Go to for SERVICEMAN; Dhw Mode Setting

Riello NXHM
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
103
ENGLISH
Keys Function
Go to the menu structure (on the home page)
ŻŹźŸ
Navigate the cursor on the display
Navigate in the menu structure
Adjust settings
7XUQRQRႇWKHVSDFHKHDWLQJFRROLQJRSHUDWLRQRU'+:PRGH
7XUQRQRURႇIXQFWLRQVLQWKHPHQXVWUXFWXUH
Come back to the up level
/RQJSUHVVIRUXQORFNORFNWKHFRQWUROOHU
8QORFNORFNVRPHIXQFWLRQVVXFKDV'+:WHPSHUDWXUHDGMXVWLQJ
Go to the next step when programming a schedule in the menu structure; and
FRQ¿UPDVHOHFWLRQWRHQWHULQWKHVXEPHQXRIWKHPHQXVWUXFWXUH
About "FOR SERVICEMAN"
"FOR SERVICEMAN" is designed for the installer to set the para-
meters.
Setting the composition of equipment.
Setting the parameters.
How to go to FOR SERVICEMAN
Go to " "> FOR SERVICEMAN. Press
" ".
Please input the password:
ADJUST ENTER
0 0 0
FOR SERVICEMAN
3UHVVŻŹWRQDYLJDWHDQGSUHVVźŸWRDGMXVWWKHQXPHULFDOYDO-
ve.
Press
" "
.
The password is indicated in the service manual;
the following pages will be displayed after putting the password:
ENTER
FOR SERVICEMAN
1. DHW MODE SETTING
2. COOL MODE SETTING
3. HEAT MODE SETTING
4. AUTO MODE SETTING
5. TEMP.TYPE SETTING
6. ROOM THERMOSTAT
1/3
7. OTHER HEATING SOURCE
8. HOLIDAY AWAY SETTINGTING
9. SERVICE CALL
10. RESTORE FACTORY SETTINGS
11. TEST RUN
12. SPECIAL FUNCTION
FOR SERVICEMAN
FOR SERVICEMAN
13. AUTO RESTART
14. POWER INPUT LIMITATION
15. INPUT DEFINE
16. CASCADE SET
17. HMI ADDRESS SET
3/3
2/3
ENTER
ENTER
3UHVVźŸWRVFUROODQG
use
" "
to
enter submenu.
10.5.1 DHW MODE SETTING
DHW = domestic hot water
Go to "
"> FOR SERVICEMAN> 1.DHW MODE SETTING.
Press
" "
. The following pages will be displayed:
1 DHW MODE SETTING
YES
YES
YES
YES
NON
ADJUST
1.1 DHW MODE
1.2 DISINFECT
1.3 DHW PRIORITY
1.4 PUMP_D
1.5 DHW PRIORITY TIME SET
5 °C
10°C
43°C
-10°C
5 MIN
1 DHW MODE SETTING
1.6 dT5_ON
1.7 dT1S5
1.8 T4DHWMAX
1.9 T4DHWMIN
1.10 t_INTERVAL_DHW
5 °C
5 °C
30 MIN
65°C
15MIN
1 DHW MODE SETTING
1.11 dT5_TBH_OFF
1.12 T4_TBH_ON
1.13 t_TBH_DELAY
1.14 T5S_DISINFECT
1.15 t_DI HIGHTEMP.
210 MIN
30 MIN
120 MIN
YES
5 MIN
1 DHW MODE SETTING
1.16 t_DI_MAX
1.17 t_DHWHP_RESTRICT
1.18 t_DHWHP_MAX
1.19 PUMP_D TIMER
1.20 PUMP_D RUNNING TIME
1/5
2/5
ADJUST
ADJUST
3/5
4/5
ADJUST
NON
1 DHW MODE SETTING
1.21 PUMP_D DISINFECT RUN
5/5
ADJUST

Related product manuals