2 GENERAL INTRODUCTION
These units are used for both heating and cooling applications and domestic hot water tanks.They can be combined with fan coil
XQLWVÀRRUKHDWLQJDSSOLFDWLRQVORZWHPSHUDWXUHKLJKHႈFLHQF\UDGLDWRUVGRPHVWLFKRWZDWHUWDQNVDQGVRODUNLWVZKLFKDUHDOO¿HOG
supplied.
A wired controller is supplied with the unit.
5RRPWKHUPRVWDW¿HOGVXSSO\FDQEHFRQQHFWHGWRWKHXQLWURRPWKHUPRVWDWVKRXOGEHNHSWDZD\IURPKHDWLQJVRXUFHZKHQVHOHFWLQJ
the installation place).
6RODUNLWIRUGRPHVWLFKRWZDWHUWDQN¿HOGVXSSO\$QRSWLRQDOVRODUNLWFDQEHFRQQHFWHGWRWKHXQLW
5HPRWHDODUPNLW¿HOGVXSSO\FDQEHFRQQHFWHGWRWKHXQLW
Operation range.
COOLING MODE
HEATING MODE
Outdoor temperature(°C)
Water flow temperature (°C)
Outdoor temperature(°C)
Water flow temperature (°C)
DOMESTIC WATER HEATING MODE
Outdoor temperature(°C)
Water flow temperature (°C)
If IBH/AHS setting is valid, only IBH/AHS turns on.
If IBH/AHS setting is invalid, only heat pump turns on.
No heat pump operation, IBH or AHS only.
Water flow temperature drop or rise interval.
If you add an optional backup heater unit, the backup heater can
increase the heating capacity during cold outdoor temperature.
The backup heater also serves as a backup in case of malfun-
ctioning and for frozen protection of the outside water piping du-
ULQJZLQWHUWLPH7KHFDSDFLW\RIEDFNXSKHDWHUIRUGLႇHUHQWXQLWV
is listed below.
Tbivalent Outdoor temperature
Capacity/Load
Ĺ
ĸ
ķ
1 Heat pump capacity.
2 Required heating capacity (site dependent).
3 Additional heating capacity provided by backup heater.
The unit have a freeze prevention function that uses the heat
pump to keep the water system safe from freezing in all condi-
tions. Since a power failure may happen when the unit is unat-
WHQGHG,WVVXJJHVWHGWRXVHDQWLIUHH]LQJÀRZVZLWFKLQWKHZD-
ter system (refer to 9.4 Water piping).
,QFRROLQJPRGHWKHPLQLPXPOHDYLQJZDWHUÀRZWHPSHUDWXUH
7VWRSKWKDWWKHXQLWFDQUHDFKLQGLႇHUHQWRXWGRRUWHPSHUDWX-
re (T4) is listed below:
Outdoor temp. (°C) 11
12 13
:DWHUÀRZWHPS& 10 9
98
Outdoor temp. (°C) 14
15 16 17
:DWHUÀRZWHPS& 8
776
Outdoor temp. (°C)
18 19 20
:DWHUÀRZWHPS&
6655
,QKHDWLQJPRGHWKHPD[LPXPOHDYLQJZDWHUÀRZWHPSHUDWXUH
7VWRSKWKDWKHDWSXPSFDQUHDFKLQGLႇHUHQWRXWGRRUWHPSH-
rature (T4) is listed below:
Outdoor temp. (°C) -25 -24 -23 -22
:DWHUÀRZWHPS& 35 35 35 37 39
Outdoor temp. (°C) -20 -19
-18 -17
:DWHUÀRZWHPS& 40 42 44 46 48
Outdoor temp. (°C) -15
-14 -13 -12
:DWHUÀRZWHPS& 50 52 54 56 58
Outdoor temp. (°C) -10~30 31 32
:DWHUÀRZWHPS& 60 59 58 57
Outdoor temp. (°C) 34 35
:DWHUÀRZWHPS& 56
55
In DHW mode, the maximum domestic hot water temperature
7VWRSWKDWKHDWSXPSFDQUHDFKLQGLႇHUHQWRXWGRRUWHPSHUD-
ture (T4) is listed below:
Outdoor temp. (°C) -25~-21 -20~-14 -15~-11 -10~-4 -5~-1
'+::DWHUÀRZWHPS& 35 40 45 48 50
Outdoor temp. (°C) 0~4 5~9 10~14 15~19 20~24
'+::DWHUÀRZWHPS& 53 55 55 53 50
Outdoor temp. (°C) 25~29 30~34 35~39 40~43
'+::DWHUÀRZWHPS& 50 48 48 45