rigert Ltd., Stairlifts
Operating manual
Nr.: AW4231
CH-6405 Immensee
Fault finding PEGASUS-NOVA-mps2
Date: 13.03.06
Page: 11/22
4 Communication
4.1 Check communication
Switch on the stairlift on the call station – key switch
Turn the encoder till “Modem Status” appears
Projected status:
“+”-symbols shown on lower line which change alternatively with “p”-symbols
If OK, proceed to point 5
if not, proceed to point 4.1.1
4.1.1 Search faults in “Modem Status”
1
st
“+”: Carriage (‘C)
2
nd
and following “+”: call stations
The number of “+”depends on the number of call stations (min 2 pcs) !
Symbols:
“+” = present, ok
“p” = polling
“f” = 1
st
fault
“F” = Fault still present
“x” = not present but required
“-“ = not present, not required
if no communication with carriage present, proceed to point 7
if no communication with a call station, proceed to point 4.1.2
Modem Status
+ + + p + - - - - -
C 1
s
4