4 Communication
4.1 Check communication
Switch on the stairlift on the call station – key switch
Turn the encoder till Modem Status” appears
Projected status:
+”-symbols shown on lower line which change alternatively with “p”-symbols
If OK, proceed to point 5
if not, proceed to point 4.1.1
4.1.1 Search faults in “Modem Status”
1
st
+”: Carriage (C)
2
nd
and following “+”: call stations
The number of +”depends on the number of call stations (min 2 pcs) !
Symbols:
+ = present, ok
p = polling
f = 1
st
fault
F = Fault still present
x = not present but required
- = not present, not required
if no communication with carriage present, proceed to point 7
if no communication with a call station, proceed to point 4.1.2
Modem Status
+ + + p + - - - - -
C 1