RIGOL Chapter 2 Basic Waveform Output
DG4000 User's Guide
2-12
To Set the Duty Cycle
Duty Cycle is defined as the percentage that the high level takes up in the whole
period as shown in the figure below.
T
t
Duty Cycle=t/T*100%
The duty cycle range is limited by the "Freq/Period" setting. Please refer to
"Signal Characteristics" in "Specifications". The default value is 50%.
Press Duty Cycle to highlight the softkey. At this point, use the numeric keyboard
to input the duty cycle value and select the unit "%" from the pop-up unit menu or
use the direction keys and knob to modify the current value. For the input method
of duty cycle value, refer to the introduction in "
Parameter Setting Method".