EasyManuals Logo
Home>Rigol>Test Equipment>DS1000 Series

Rigol DS1000 Series Programming Guide

Rigol DS1000 Series
97 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
RIGOL
© 2008 RIGOL Technologies, Inc.
Programming Guide for DS1000/DS1000CA Series
2-39
3. :CHANnel<n>:DISPlay
Command Format:
:CHANnel<n>:DISPlay{ON|OFF}
Explanation:
The command is to set channel n (n is 1 or 2) ON or OFF.
Query Format:
:CHANnel<n>:DISPlay?
Returned Format:
Query returns ON or OFF. The double quotes are not returned.
Example:
:CHANnel2:DISPlayON Set Channel 2 Display On
:CHANnel2:DISPlay? Query returns ON
4. :CHANnel<n>:INVert
Command Format:
:CHANnel<n>:INVert{ON|OFF}
Explanation:
The command is to set the waveform invert ON or OFF.
Query Format:
:CHANnel<n>:INVert?
Returned Format:
Query returns ON or OFF. The double quotes are not returned.
Example:
:CHANnel2:INVertOFF Set the waveform invert of Channel 2 to OFF.
:CHANnel2:INVert? Query returns OFF.