RIGOL
© 2008 RIGOL Technologies, Inc.
Programming Guide for DS1000/DS1000CA Series
2-55
2. Set the edge trigger condition
An edge trigger occurs when the trigger input meets a specified voltage level in
the specified slope direction.
2.1 :TRIGger:EDGE:SLOPe
Command Format:
:TRIGger:EDGE:SLOPe{POSitive|NEGative}
Explanation:
The command is to set the trigger edge to be Positive or Negative.
Query Format:
:TRIGger:EDGE:SLOPe?
Returned Format:
Query returnsPOSITIVE or NEGATIVE. The double quotes are not returned.
Example:
:TRIGger:EDGE:SLOPePOSitive Set the trigger edge as positive
:TRIGger:EDGE:SLOPe? Query returns POSITIVE