EasyManuals Logo
Home>Rigol>Test Equipment>DS1000 Series

Rigol DS1000 Series Programming Guide

Rigol DS1000 Series
97 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #87 background imageLoading...
Page #87 background image
RIGOL
© 2008 RIGOL Technologies, Inc.
Programming Guide for DS1000/DS1000CA Series
2-79
3. :DIGital<n>:POSition
Command Format:
:DIGital<n>:POSition<position>
Explanation:
The command is to set the size of the digital waveform. When the size of the
waveform is large, you can see the waveform on the screen from channels 0~7.
When the size of the waveform is small, you can see the waveform on the screen
from channels 0~15.
The range of <n>is 0~15;
<position> is 0~7 (if display size = large)
0~15 (if display size = small)
Query Format:
:DIGital<n>:POSition?
Returned Format:
Query returns the set value of <position>.
Example:
:DIGital2:POSition3
Set the count of waveform for the digital Channel 2 to 3.
:DIGital2:POSition
Query returns 3.
4. :LA:THReshold
Command Format:
:LA:THReshold<value>[suffix]
Explanation:
The command is to set the threshold as TTL, CMOS, ECL or ueser defined.
<Value> can be CMOS, ECL, TTL and User Defined, the <User Defined>
value is in NR3 format from -8.00 to +8.00
[suffix] can be V, mV or uV.

Other manuals for Rigol DS1000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1000 Series and is the answer not in the manual?

Rigol DS1000 Series Specifications

General IconGeneral
BrandRigol
ModelDS1000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals