RIGOL Programming Introduction
Programming Guide for DS1000CA Series
1-6
Parameter Type
The commands contains 5 kinds of parameters, different parameters has different
setting methods.
1. Boolean
The parameter should be OFF or ON, for example:
:MEASure:TOTal {ON|OFF}
Thereinto, ON denotes to trun on (enable) this function and OFF denoets
to turn off (disable).
2. Consecutive Integer
The parameter should be a consecutive integer, for example:
:DISPlay:BRIGhtness <ncount>
Thereinto,<ncount> could be an integer between 0 and 32 (including 0 and
32).
3. Consecutive Real Number
The parameters could be any value within effective range and precision
permiting, for example:
:TRIGger:EDGE:SENSitivity <count>
Thereinto, <count> could be a real number between 0.1 and 1(including 0.1
and 1).
4. Discrete
The parameters can only be the cited value, for example:
:ACQuire:AVERages <count>
Thereinto, <count> could be 2, 4, 8, 16, 32, 64, 128, 256.
5. ASCII Character String
The parameter should a combination of ASCII character string, for example:
:TRIGger:MODE <mod>
Thereinto, <mod> could be EDGE, PULSe, VIDEO, SLOPe or
ALTernation.

Other manuals for Rigol DS1000CA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1000CA Series and is the answer not in the manual?

Rigol DS1000CA Series Specifications

General IconGeneral
BrandRigol
ModelDS1000CA Series
CategoryTest Equipment
LanguageEnglish

Related product manuals