Programming Introduction RIGOL
Programming Guide for DS1000CA Series
2-25
PULSe Trigger
1. :TRIGger:PULSe:MODE
Command Format:
:TRIGger:PULSe:MODE <mode>
:TRIGger:PULSe:MODE?
Function Explanation:
The commands are used o set and query the pulse condition. The options of
<mode> are +GREaterthan, +LESSthan, +EQUal, -GREaterthan,
-LESSthan or -EQUal.
Returned Format:
Query returns “+GREATER THAN”, “+LESS THAN”, “+EQUAL, -GREATER
THAN”, -LESS THAN” or -EQUAL.
Example:
:TRIG:PULS:MODE +GRE Set the pulse mode as “+GREaterthan
:TRIG:PULS:MODE? Query returns “+GREATER THAN”
2. :TRIGger:PULSe:SENSitivity
Command Format:
:TRIGger:PULSe:SENSitivity <count>
:TRIGger:PULSe:SENSitivity?
Function Explanation:
The commands are used to set and query the trigger sensitivity of PULSe
tigger. The range of <count> is 0.1~1.
Returned Format:
Query returns the set value of <count> in scientific numeric notation in div.
Example:
:TRIG:PULS:SENS 0.5 Set the trigger sensitivity as 0.5div