Programming Introduction RIGOL
Programming Guide for DS1000CA Series
2-5
1. :RUN
Command Format:
:RUN
Function Explanation:
This command initiates the oscilloscope to acquire waveform data. To stop
acquisition, please execute :STOP command.
2. :STOP
Command Format:
:STOP
Function Explanation:
This command controls the oscilloscope to stop acquiring data. To restart the
acquisition, please execute :RUN command.
3. :AUTO
Command Format:
:AUTO
Function Explanation:
This command is used to control the oscilloscope to evaluate all waveform
characteristics and set the optimum conditions to display the waveforms,
4. :HARDcopy
Command Format:
:HARDcopy
Function Explanation:
This command is to extract the current information on the screen, and then
copy the bitmap into the U disc in the form of HardCopyxxx.bmp. (Note:This
command is unavailable in file systems).