II DS1000Z Quick Guide
Safety Requirement
General Safety Summary
1. Only the exclusive power cord
designed for the instrument and
authorized for use within the local
country could be used.
2. Ensure that the instrument is
safely grounded.
3. Connect the probe correctly.
4. Observe all terminal ratings.
5. Use proper overvoltage protection.
6. Do not operate without covers.
7. Do not insert objects into the air
outlet.
8. Use the proper fuse.
9. Avoid circuit or wire exposure.
10. Do not operate the instrument with
suspected failures.
11. Provide adequate ventilation.
12. Do not operate in wet conditions.
13. Do not operate in an explosive
atmosphere.
14. Keep instrument surfaces clean and
dry.
15. Prevent electrostatic impact.
16.
Handle with caution.
Safety Notices and Symbols
Safety Notices in this Manual:
WARNING
Indicates a potentially hazardous situation or practice which, if not
avoided, will result in serious injury or death.
CAUTION
Indicates a potentially hazardous situation or practice which, if not
avoided, could result in damage to the product or loss of important data.
Safety Terms on the Product:
DANGER
It calls attention to an operation, if not correctly performed, could
result in injury or hazard immediately.
WARNING
It calls attention to an operation, if not correctly performed, could
result in potential injury or hazard.
CAUTION
It calls attention to an operation, if not correctly performed, could
result in damage to the product or other devices connected to the
product.
Safety Symbols on the Product:
Hazardous
Voltage
Safety
Warning
Protective
Earth
Terminal
Chassis
Ground
Test
Ground

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1054 and is the answer not in the manual?

Rigol DS1054 Specifications

General IconGeneral
Bandwidth50 MHz
Channels4
Sample Rate1 GSa/s
Vertical Sensitivity1 mV/div to 10 V/div
Timebase Range5 ns/div to 50 s/div
Vertical Resolution8 bits
Display Resolution800x480 pixels
InterfacesUSB Host, USB Device, LAN
Input CouplingDC, AC, GND
Display7 inch TFT LCD
Trigger TypesEdge, Pulse, Video, Slope, Alternate
Waveform Capture Rate30, 000 wfms/s
Input Impedance1 MΩ ± 2%
Memory Depth24 Mpts (Single Channel), 12 Mpts (Dual Channel)

Related product manuals