Automatic operation
Once the combustion chamber door has been closed, the operating status log
check is issued on the touch display.
Manual Mode Su 15.03.2015
15:55
Manual Mode
Split Logs Check
Heating Power
Depending on temperature, it takes up to 20 minutes until the status display
changes to log operation and the stove starts to regulate the burn-off. This time
is required to obtain an appropriate firebed.
Manual Mode Su 15.03.2015
15:55
Manual Mode
Heating Power
Split Logs Mode
The time to add logs varies according to the respective ambient influences,
generally the addition phase takes approx. 5-10 min. The status display on the
touch display changes between log operation and please add wood.
Manual Mode Su 15.03.2015
15:55
Manual Mode
Put On Split Logs
Heating Power
If an addition phase is missed, no logs may be added subsequently since the
ignition of these cannot be guaranteed. The status display on the touch display
changes between log operation and DO NOT add wood.
Manual Mode Su 15.03.2015
15:55
Manual Mode
DO NOT put Logs
Heating Power
Note
The heating time, room temperature and frost protection functions as well
as external demand are deactivated during the entire log operation. These
functions are only re-activated after log operation.
Manual Regulation
(CURRENTLESS OPERATION)
Note
The combi stove must be disconnected from the mains for manual operation.
Note
Any procedure other than that stated below may lead to damage to the
components and inevitably to loss of warranty
Insert the socket spanner supplied in the sleeve as shown. Turn it clockwise
until a slight stop is detected.
Remove the socket spanner from the opening and insert it again in the horizontal
position
Turn the spanner ant-clockwise until it is flush with the marking in the side panel
(approx. 45°). It is now in heating up position.
Turn the spanner after the heating-up phase anti-clockwise step by step to
regulate the burn-off manually. (Secondary air range)
Note
Always ensure that the stove has enough air for combustion.