28
Errors
Display Meaning Action to be taken
ERROR
NO
PELLETS
There are no longer sufficient pellets in the
container.
Acknowledge error message and refill pellets.
ERROR
NOT
IGNITED
Ignition cannot be concluded due to lack of ignition
detection.
Acknowledge error message and check pellet
supply container. Open combustion chamber door
and clean fire trough if necessary. Stove can then
be restarted.
ERROR
AIR FLAPS
DEFECT
The air flaps required for automatic air regulation
cannot move to their position correctly.
Acknowledge error message and again wait for air
flap calibration.
ERROR
GRID
DEFECT
The dump grate cannot complete the dump process
provided for.
Acknowledge error message and check for any
blockage of the dump grate at the fire trough.
ERROR
DISCHARGE MOTOR
DEFECT
The discharge motor for pellet conveying out of the
container can no longer be actuated.
Acknowledge error message and restart stove.
ERROR
INSERTION MOTOR
DEFECT
The insertion motor for pellet conveying into the
burnpot can no longer be actuated.
Acknowledge error message and restart stove.
ERROR
STOVE
OVERHEATED
The STL (safety temperature limiter) has activated.
The stove overheated and switched off automati-
cally due to a safety risk.
Manually deblock STL at stove rear wall (press)
acknowledge error message and restart stove
ERROR
FLAME SENSOR
DEFECT
The flame temperature sensor in the combustion
chamber does not give a realistic temperature to
the stove control system.
Acknowledge error message and restart stove.
ERROR
FAN
DEFECT
The flue gas blower specified speed was not
reached.
Acknowledge error message and restart stove.