Infinity REU-V3232W /HD250E REU-V3232WC - 20 - Issue 1 - 8/09/03 ©Rinnai
13. Dip Switch Settings
WARNING: Dip Switch settings must only be changed by an authorised person.
Dip Switches explained
Dip Switches
Gas Type
LP Natural
1: OFF 1: ON
2: OFF 2: OFF
Combustion
Computer Programming
Gas Type
Temperature
Computer Programming
Combustion (forced high or low)
LEGEND
(black section indicates
position of switch)
Normal Combustion
Forced ‘Low’ Combustion
Forced ‘High’ Combustion
Switch is always in OFF position for Infinity 32e and HD 70e
Note :
Only alter gas type positions when
converting from one gas type to another.
For gas conversion instructions refer to
page 41.