10 | Rinnai INFINITY EF26 and A-Series installation guide 01-20
Water delivery temperature
Requirements of AS/NZS 3500 MUST BE considered regarding the temperature limitations of hot
water supplied to areas used primarily for personal hygiene. The temperature of these areas may
be limited to 55 °C or less.
If the appliance is to deliver water primarily for the purposes of personal hygiene in an early
childhood centre, school, nursing home or similar facility as dened in AS/NZS 3500.4, a
Temperature Limiting Device (TLD), such as a tempering valve may be required, even if the
appliance is set to 55 °C or less. For these types of applications contact Rinnai.
Requirements for Rinnai INFINITY units installed without controllers
Diagram 1 - 55 °C Appliance
55 °C
Diagram 2 - Not a 55 °C Appliance
(TLD = Temperature Limiting Device)
Hot
Cold
Gas
Ensuite
Laundry
Bathroom
Kitchen
Hot
Cold
Gas
Kitchen
> 55 °C
Laundry
> 55 °C
Ensuite
< 55 °C
Bathroom
< 55 °C
TLD
When the Rinnai INFINITY is set to deliver water at a temperature higher than 55 °C, it will be
necessary to t a Temperature Limiting Device for delivery to areas used for the purposes of
personal hygiene.