Page 16 003X-607-121
6. Error Messages
6.1. Weighing Errors
Error Description Resolution
(U - - - - -) The weight is below
the minimum allowable
weight reading.
Increase the weight or
decrease the minimum
allowable weight
reading.
(O - - - - -) The weight is above
the maximum
allowable weight
reading.
Warning - overloading
may damage
mechanical scale
elements.
Check the condition of
load cell connections.
Check for damaged
load cell.
(ZERO)
(ERROR)
The weight reading is
beyond the limit set for
Zero operation. The
operation of the
<ZERO> key is limited
in the setup during
installation. The
indicator cannot be
Zeroed at this weight.
Increase the Zero
Range (OPTION:
Z.RANGE) or use the
<TARE> key instead.
(STABLE)
(ERROR)
Scale motion has
prevented a <ZERO>,
<TARE> or <PRINT>
operation from
occurring on
command.
Try the operation again
once the scale is
stable.