Operator Manual Rev 1.21
Page 6 003X-607-121
Key Description
ZERO: The <ZERO> key is used to perform a
Zero adjustment on the scale display when an
empty scale has drifted away from a true zero
reading.
• The Zero adjustment is stored when power is
removed and is re-used when next powered
up.
• Long Press: When the indicator is set to
Industrial mode a long press of the <ZERO>
key will remove any stored zero adjustment.
TARE: The <TARE> key is used to temporarily
set the scale to zero (such as cancelling the
weight of a carton before performing a filling
operation). The display will show the Net weight
and the Net annunciator will be lit.
• The <TARE> key can operate in all modes
(ie. Industrial, OIML and NTEP).
• The weight tared is deducted from the allowable
range of the scale, reducing the maximum
weight that can be displayed.
• The Tare adjustment is stored when power is
removed and is re-used when next powered
up.
GROSS/NET: The <GROSS/NET> key toggles
the weight display between the Gross weight and
the Net weight (provided that a Tare has
previously been acquired using the <TARE> key).