20 AGM - Installation and Programming Instructions
Command Description Programming Options Default
F1RS to F1RS: Follow Me Event
Restore
Choose which restore events will be
reported to each Follow Me number.
1: Input 1
2: Input 2
3: Input 3
4: Input 4
5: Tamper
6: PSTN loss
7: GSM trouble
8: Main power loss
9: Low battery
V1RE to V4RE : Voice Message
Assignment to Follow Me
Choose which voice message will follow a
specific triggering of an event or message
1: Input 1
2: Input 2
3: Input 3
4: Input 4
5: Tamper
6: PSTN loss
8: Main power loss
9: Low battery
11: Periodic test
0
Monitoring Station
M1TY or M2TY: Monitoring Station Channel report Type
The manner of reporting events to the MS. For additional
information refer to page 10.
1: SMS
2: GPRS
1
M1AN or M2AN: Monitoring Station Account Number
A six digit customer account number assigned by the
Monitoring Station.
Max. 6 digits 111111
222222
M1TL or M2TL: Monitoring Station Telephone Number Max. 32 digits -
M1IP or M2IP: Monitoring Station IP Address Max. 15 digits -
M1PT or M2PT: Monitoring Station Port Max. 5 digits -
MSSP: Monitoring Station report
backup
The Report Backup menu contains options
that enable the routing of events reporting
to the Monitoring Station channels.
0: Don’t Call
1: Call 1st
2: Call 2nd
3: Call All
4: Second back up first
5: First back up
second
4
MSRE: Monitoring Station Report
Events
1: Input 1
2: Input 2
3: Input 3
4: Input 4
5: Tamper
6: PSTN loss
8: Main power loss
9: Low battery
11: Periodic test
-
MSRS: Monitoring Station Events
Restore
1: Input 1
2: Input 2
3: Input 3
4: Input 4
5: Tamper
6: PSTN loss
8: Main power loss
9: Low battery
MSCF: Monitoring Station Communication Format
The communication protocol used by the digital receiver at
the Monitoring Station.
0420: Contact ID
0700: SIA
0420
Monitoring Station :Report Codes
RI1E Input 1 event 4 digits (MSCF=0420)
2 chars (MSCF=0700)
0130
(Intruder)
RI2E Input 2 event 4 digits (MSCF=0420)
2 chars (MSCF=0700)
0120
(Panic)
RI3E Input 3 event 4 digits (MSCF=0420)
2 chars (MSCF=0700)
0110
(Fire
Alarm)
RI4E Input 4 event 4 digits (MSCF=0420)
2 chars (MSCF=0700)
0100
(Medical)
RI1R Input 1 restore event 4 digits (MSCF=0420)
2 chars (MSCF=0700)
0130
(Intruder)
RI2R Input 2 restore event 4 digits (MSCF=0420)
2 chars (MSCF=0700)
0120
(Panic)
RI3R Input 3 restore event 4 digits (MSCF=0420)
2 chars (MSCF=0700)
0110
(Fire
Alarm)