EasyManua.ls Logo

Risco AGM - Page 20

Risco AGM
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20 AGM - Installation and Programming Instructions
Command Description Programming Options Default
F1RS to F1RS: Follow Me Event
Restore
Choose which restore events will be
reported to each Follow Me number.
1: Input 1
2: Input 2
3: Input 3
4: Input 4
5: Tamper
6: PSTN loss
7: GSM trouble
8: Main power loss
9: Low battery
V1RE to V4RE : Voice Message
Assignment to Follow Me
Choose which voice message will follow a
specific triggering of an event or message
1: Input 1
2: Input 2
3: Input 3
4: Input 4
5: Tamper
6: PSTN loss
8: Main power loss
9: Low battery
11: Periodic test
0
Monitoring Station
M1TY or M2TY: Monitoring Station Channel report Type
The manner of reporting events to the MS. For additional
information refer to page 10.
1: SMS
2: GPRS
1
M1AN or M2AN: Monitoring Station Account Number
A six digit customer account number assigned by the
Monitoring Station.
Max. 6 digits 111111
222222
M1TL or M2TL: Monitoring Station Telephone Number Max. 32 digits -
M1IP or M2IP: Monitoring Station IP Address Max. 15 digits -
M1PT or M2PT: Monitoring Station Port Max. 5 digits -
MSSP: Monitoring Station report
backup
The Report Backup menu contains options
that enable the routing of events reporting
to the Monitoring Station channels.
0: Don’t Call
1: Call 1st
2: Call 2nd
3: Call All
4: Second back up first
5: First back up
second
4
MSRE: Monitoring Station Report
Events
1: Input 1
2: Input 2
3: Input 3
4: Input 4
5: Tamper
6: PSTN loss
8: Main power loss
9: Low battery
11: Periodic test
-
MSRS: Monitoring Station Events
Restore
1: Input 1
2: Input 2
3: Input 3
4: Input 4
5: Tamper
6: PSTN loss
8: Main power loss
9: Low battery
MSCF: Monitoring Station Communication Format
The communication protocol used by the digital receiver at
the Monitoring Station.
0420: Contact ID
0700: SIA
0420
Monitoring Station :Report Codes
RI1E Input 1 event 4 digits (MSCF=0420)
2 chars (MSCF=0700)
0130
(Intruder)
RI2E Input 2 event 4 digits (MSCF=0420)
2 chars (MSCF=0700)
0120
(Panic)
RI3E Input 3 event 4 digits (MSCF=0420)
2 chars (MSCF=0700)
0110
(Fire
Alarm)
RI4E Input 4 event 4 digits (MSCF=0420)
2 chars (MSCF=0700)
0100
(Medical)
RI1R Input 1 restore event 4 digits (MSCF=0420)
2 chars (MSCF=0700)
0130
(Intruder)
RI2R Input 2 restore event 4 digits (MSCF=0420)
2 chars (MSCF=0700)
0120
(Panic)
RI3R Input 3 restore event 4 digits (MSCF=0420)
2 chars (MSCF=0700)
0110
(Fire
Alarm)