6. Product information
49
DeutschEnglishFrancaisEspanolItaliano
6.1 How it works
You use the RKMultiControl controller to move Rose+Krieger drives.
According to the design, you can connect up to two (with the RKMultiControl duo) or up to
four (with the RKMultiControl quadro) drives to the controller. You use a hand switch to operate
the controller. If more than two or four drives need to be moved synchronously, you have the op-
tion to connect up to eight controllers.
6.2 Technical specification
Type/Model RKMultiControl duo/quadro RKMultiControl duo silent
Dimensions W × H × L 110 × 62 × 335 mm
Weight 2.5 kg
Supply voltage (primary)
(depending on design)
230V (±10%) AC 50/60 Hz
115V (±10%) AC 50/60 Hz
Type of protection IP 30
max. current drain (primary)
RKMultiControl duo:
2A (230V AC, 50/60 Hz)
RKMultiControl duo:
4A (115V AC, 50/60 Hz)
RKMultiControl quadro:
2A (230V AC, 50/60 Hz)
RKMultiControl quadro:
4A (115V AC, 50/60 Hz)
RKMultiControl duo silent:
2A (230V AC, 50/60 Hz)
RKMultiControl duo silent:
4A (115V AC, 50/60 Hz)
max. output current 6A per drive, total 12A 5A per drive, total 10A
Duty cycle 20 % duty cycle/10 min runtime 10 % duty cycle/10 min runtime
Rated output 300 VA 250 VA
Protection class II (insulated construction)
Primary fuse rating
at 230V: 2.5A slow-blow
at 115V: 5A slow-blow
Secondary fuse rating
at 230V: 12.5A slow-blow
at 115V: 12.5A slow-blow
Ambient temperature +5 °C to +40 °C
Ambient air pressure from 700 hPa to 1600 hPa
Relative humidity 30 % to 75 %