C
100
(Un
i
t: mm)
C
400
(Un
i
t: mm)
C
410
(Un
i
t: mm)
C
700
(Un
i
t: mm)
C
900
(Un
i
t: mm)
P
a
nel th
i
ckness: 1 to 5 mm or 5 to 9 mm (
C
100)
1 to 8 mm (
C
400/410/700/900)
2
.
3
M
oun
ti
ng
p
r
o
ce
du
r
es
C
100
W
h
e
n
t
h
e c
on
tr
o
llers are m
oun
te
d
on
p
a
n
el
w
it
h
1 t
o
5 mm i
n
t
h
ick
n
ess
S
i
nce the mount
i
ng brackets are already
i
nstalled on the controller,
i
nsert the
controller
i
nto the panel front w
i
thout
removal of the brackets.
W
h
e
n
t
h
e c
on
tr
o
llers are m
oun
te
d
on
p
a
n
el
w
it
h
5 t
o
9 mm i
n
t
h
ick
n
ess
Remove the mount
i
ng brackets from the
controller w
i
th a slotted screwdr
i
ver.
E
ngage each mount
i
ng bracket w
i
th holes
marked w
i
th 5-9 on the hous
i
ng and then
i
nsert the controller
i
nto the panel from the
panel front.
C
400/410/700/900
1
.
P
repare the panel cutout as
spec
i
f
i
ed
i
n
2
.2
D
ime
n
si
on
s.
2. Insert the
i
nstrument through the
panel cutout.
3. Insert an upper mount
i
ng bracket
along the bracket
i
nsert
i
on groove
from the back, and then engage a
project
i
on at the bracket end w
i
th a
recess at the groove front and also
i
nsert metal f
i
tt
i
ng legs
i
nto slots.
4. T
i
ghten a bracket setscrew from the rear of the bracket w
i
th
P
h
i
ll
i
ps
screwdr
i
ver.
D
o not overt
i
ghten the bracket setscrew.
5. The other mount
i
ng bracket should be
i
nstalled the same way descr
i
bed
i
n 3. and 4.
C
900
i
s used
i
n the above f
i
gures for explanat
i
on, but the same
mount
i
ng procedures also apply to
C
400/410/700.
3
. WI
R
I
N
G
3
.
1
Wiri
ng
C
a
u
ti
on
s
F
or thermocouple
i
nput, use the appropr
i
ate compensat
i
on w
i
re.
F
or RT
D
i
nput, use low res
i
stance lead w
i
re w
i
th no d
i
fference
i
n res
i
stance
between the three lead w
i
res.
To avo
i
d no
i
se
i
nduct
i
on, keep
i
nput s
i
gnal w
i
re away from
i
nstrument
power l
i
ne, load l
i
nes and power l
i
nes of other electr
i
c equ
i
pment.
S
i
gnal connected to
V
oltage
i
nput and
C
urrent
i
nput shall be low voltage
def
i
ned as “
SE
L
V
” c
i
rcu
i
t per I
E
C
60950-1.
If there
i
s electr
i
cal no
i
se
i
n the v
i
c
i
n
i
ty of the
i
nstrument that could affect
operat
i
on, use a no
i
se f
i
lter.
-
S
horten the d
i
stance between the tw
i
sted power supply w
i
re p
i
tches to
ach
i
eve the most effect
i
ve no
i
se reduct
i
on.
-
A
lways
i
nstall the no
i
se f
i
lter on a grounded panel. M
i
n
i
m
i
ze the w
i
r
i
ng
d
i
stance between the no
i
se f
i
lter output and the
i
nstrument power supply
term
i
nals to ach
i
eve the most effect
i
ve no
i
se reduct
i
on.
-
D
o not connect fuses or sw
i
tches to the no
i
se f
i
lter output w
i
r
i
ng as th
i
s w
i
ll
reduce the effect
i
veness of the no
i
se f
i
lter.
A
llow approx
i
mately 5 to 6 seconds for contact output when the
i
nstrument
i
s turned on. Use a delay relay when the output l
i
ne
i
s used for an external
i
nterlock c
i
rcu
i
t.
P
ower supply w
i
r
i
ng must be tw
i
sted and have a low voltage drop.
Th
i
s
i
nstrument w
i
th 24
V
power supply
i
s not prov
i
ded w
i
th an overcurrent
protect
i
on dev
i
ce.
F
or safety
i
nstall an overcurrent protect
i
on dev
i
ce (such
as fuse) w
i
th adequate break
i
ng capac
i
ty close to the
i
nstrument.
-
F
use type: T
i
me-lag fuse (
A
pproved fuse accord
i
ng I
E
C
60127-2 and/or
UL248-14)
-
F
use rat
i
ng: Rated current: 0.5
A
F
or an
i
nstrument w
i
th 24
V
power supply
i
nput, supply power from
SE
L
V
c
i
rcu
i
t def
i
ned as I
E
C
60950-1.
A
su
i
table power supply should be cons
i
dered
i
n end-use equ
i
pment. The
power supply must be
i
n compl
i
ance w
i
th a l
i
m
i
ted-energy c
i
rcu
i
ts
(max
i
mum ava
i
lable current of 8
A
).
M
ount
i
ng bracket
H
ole for 5 to 9 mm
Hole for 1 to 5 mm
Mount
i
ng bracket
To prevent electr
i
c shock or
i
nstrument fa
i
lure, do not turn on
the power unt
i
l all w
i
r
i
ng
i
s completed. Make sure that the
w
i
r
i
ng
i
s correct before apply
i
ng power to the
i
nstrument.
e
t
ew
Insert
reces
B
rac
i
nsert
i
on
groove
S
lot
OUT
M
i
n
i
m
i
z
e
d
i
stance
Instrument
P
ower
term
i
nals
IN
Tw
i
st these l
i
adw
i
res
S
horten d
i
stance between
p
i
tches
Instrum
ent power
No
i
se f
i
lter
96
48
12
100
91
100
45
25
+
0
.
6
0
30
92
+
0.8
0
43
92
30
+
0
.
8
0
25
45
+0.6
0
48
96
12 100
91
100
43
8 100
48
48
(
53
)
44
44
25 45
+
0.6
0
45
+
0
.
6
0
25
12
100
77
67
.
6
72
72
67
.
6
25
68
68
30
+
0
.
7
0
+0.7
0
96
96
12
100
91
(
100
)
91
30
92
+
0
.
8
0
25
92
+0.8
0
WA
RN
I
N
G
!

Other manuals for RKC INSTRUMENT REX-C100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RKC INSTRUMENT REX-C100 and is the answer not in the manual?

RKC INSTRUMENT REX-C100 Specifications

General IconGeneral
BrandRKC INSTRUMENT
ModelREX-C100
CategoryController
LanguageEnglish

Related product manuals