EasyManua.ls Logo

RKC INSTRUMENT REX-C100 - Terminal Configuration

RKC INSTRUMENT REX-C100
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
3
.
2
T
e
rmi
n
a
l
C
on
fi
gu
r
a
ti
on
P
o
wer supply
C
ontrol output
Input
NO: N
ormally open
6
7
8
9
10
14
12
1
2
3
4
5
C
T
i
nput
C
urr
ent
transformer
i
nput
11
12
C
T
T
C
i
nput
T
C
8
9
RT
D
i
nput
A
B
B
RT
D
8
9
10
C
100
13
11
A
larm output
Relay contact
A
LM1
A
LM2
NO
NO
3
2
1
A
larm 2, Heater break
alarm or
C
ontrol loop
break alarm
A
larm 1 or
C
ontrol loop
break alarm
OUT
T2
T1
G
3
5
4
Tr
i
gger for
tr
i
ac dr
i
v
i
ng
OUT
5
4
V
oltage pulse/
C
urrent
Relay contact
NO
OUT
4
5
Term
i
nals wh
i
ch are not used accord
i
ng to the controlle
r
type are all removed.
When control output
i
s tr
i
gger output for tr
i
ac dr
i
v
i
ng, the
number of alarm output po
i
nts becomes 1.
Use the solderless term
i
nal appropr
i
ate to the scre
w
s
i
ze.
S
crew s
i
ze: M3 x 6
Recommended t
i
ghten
i
ng torque:
0.4 N
m [4 kgf cm]
S
pec
i
f
i
ed solderless term
i
nals:
W
i
th
i
solat
i
on
A
ppl
i
cable w
i
re:
S
ol
i
d/tw
i
sted w
i
re of 0.25 to
1.65 mm
2
Make sure that dur
i
ng f
i
eld w
i
r
i
ng parts of conductors
can not come
i
nto contact w
i
th adjacent conduct
i
ve
parts.
V
oltage/
C
urrent
8
9
6.2 mm (0.24
i
nch) or less
24
V
DC
100
240
V
AC
7
6
7
6
L
N
AC
24
V
7
6
L
N
P
ower suppl
y
C
ontrol output
NO: N
ormally open
N
C
: Normally closed
W,
A
act
i
on types
Relay contact
F
,
D
act
i
on types
N
C
NO
OUT
6
7
8
C
400
,
C
410
,
C
900
1
2
3
4
5
6
7
8
10
11
9
12
13
14
15
16
17
18
19
20
22
23
21
24
Ground
1
Term
i
nals wh
i
ch are not used accord
i
ng to the controller type
are all removed.
A
n example of the
C
900
i
s descr
i
bed here, the same w
i
r
i
ng
examples also apply to
C
400/410. Term
i
nal numbers 17 to 24
are not prov
i
ded for
C
400/410.
Use the solderless term
i
nal appropr
i
ate to the screw s
i
ze.
S
crew s
i
ze: M3 x 6
Recommended t
i
ghten
i
ng torque: 0.4 N m [4 kgf cm]
S
pec
i
f
i
ed solderless term
i
nals: W
i
th
i
solat
i
on
A
ppl
i
cable w
i
re:
S
ol
i
d/tw
i
sted w
i
re of 0.25 to 1.65 mm
2
Make sure that dur
i
ng f
i
eld w
i
r
i
ng parts of conductors can not
come
i
nto contact w
i
th adjacent conduct
i
ve parts.
OUT
T2
T1
G
6
8
7
Tr
i
gger for
tr
i
ac dr
i
v
i
ng
OUT
8
7
V
oltage pulse/
C
urrent
Relay contact
NO
OUT2
NO
OUT1
5
6
7
8
OUT2
OUT1
5
6
7
8
Input
C
urrent
transformer
i
nput
13
12
C
T
A
larm output
100
240
V
A
C
24
V
DC
24
V
A
C
3
3
2
3
2
L
N
L
N
Relay contact
A
LM1
A
LM2
NO
NO
11
1
9
A
larm 1 or
C
ontrol loop
break alarm
A
larm 2, Heater break
alarm or
C
ontrol loop
break alarm
C
T
i
nput
V
oltage pulse/
C
urrent
8.1 mm (0.32
i
nch) or less
T
C
i
nput
T
C
15
1
RT
D
i
nput
B
B
A
RT
D
14
15
16
V
oltage/
C
urrent
15
16
2
C
700
1
2
3
4
5
6
7
10
8
11
12
13
14
15
16
18
19
17
20
6.2 mm (0.24
i
nch)
or less
8.1 mm (0.32
i
nch)
or less
S
crew s
i
ze: M3 x 6
(Term
i
nal No. 1 to 10)
(
P
t
i
l
A
l
S
crew s
i
ze: M3 x 8
(Term
i
nal No. 11 to 13)
(
I
t
t
i
l
)
9
P
ower suppl
y
C
ontrol output
NO: N
ormally open
N
C
: Normally closed
W,
A
act
i
on types
Relay contact
F
,
D
act
i
on types
N
C
NO
OUT
5
6
7
Ground
1
Term
i
nals wh
i
ch are not used accord
i
ng to the controller type
are all removed.
Use the solderless term
i
nal appropr
i
ate to the screw s
i
ze.
OUT
T2
T1
G
5
7
6
Tr
i
gger for
tr
i
ac dr
i
v
i
ng
OUT
7
6
V
oltage pulse/
C
urrent
Relay contact
NO
OUT2
NO
OUT1
4
5
6
7
OUT2
OUT1
4
5
6
7
100 240
V
A
C
24
V
DC
24
V
A
C
3
3
2
2
3
2
L
N
L
N
V
oltage pulse/
C
urrent
Input
C
urrent
transformer
i
nput
20
19
C
T
A
larm output
Relay contact
A
LM1
A
LM2
NO
NO
10
9
8
A
larm 1 or
C
ontrol loop
break alarm
A
larm 2, Heater break
alarm or
C
ontrol loop
break alarm
C
T
i
nput
T
C
i
nput
T
C
12
13
RT
D
i
nput
B
B
A
RT
D
11
12
13
V
oltage/
C
urrent
12
13
Recommended t
i
ghten
i
ng torque: 0.4 N m [4 kgf cm]
S
pec
i
f
i
ed solderless term
i
nals: W
i
th
i
solat
i
on
A
ppl
i
cable w
i
re:
S
ol
i
d/tw
i
sted w
i
re of 0.25 to
1.65 mm
2
Make sure that dur
i
ng f
i
eld w
i
r
i
ng parts of conductors can not
come
i
nto contact w
i
th adjacent conduct
i
ve parts.
S
p
ec
ificati
on
s
I
npu
t
:
I
npu
t t
y
p
e
:
Th
ermocouple:
K
, J, R,
S
,
B
,
E
, T, N,
P
LII,
W5Re/W26Re, U, L
Input
i
mpedance:
A
pprox. 1 M
RT
D
:
P
t100, J
P
t100
V
oltage: 0 to 5
V
DC
, 1 to 5
V
DC
Input
i
mpedance: 250 k or more
C
urrent: 0 to 20 m
A
DC
, 4 to 20 m
A
DC
Input
i
mpedance:
A
pprox. 250
S
am
p
li
ng
cycle
:
0.5 seconds
I
npu
t ra
ng
e
:
Refer to I
npu
t ra
ng
e ta
b
le
C
on
tr
o
l m
et
hod
:
P
I
D
control
ON/O
FF
,
P
,
P
I, or
P
D
act
i
ons
i
s ava
i
lable
C
on
tr
o
l
ou
t
pu
t
:
Relay contact output: 250
V
A
C
, 3
A
(Res
i
st
i
ve load)
E
lectr
i
cal l
i
fe:
300,000 t
i
mes or more (Rated load)
V
oltage pulse output: 0/12
V
DC
(Load res
i
stance 600 or more)
C
urrent output: 4 to 20 m
A
DC
(Load res
i
stance 600 or less)
Tr
i
gger output for tr
i
ac dr
i
v
i
ng:
Zero cross method for med
i
um
capac
i
ty tr
i
ac dr
i
v
i
ng (100
A
or less)
Load voltage used:
100
V
A
C
l
i
ne, 200
V
A
C
l
i
ne
Load used: Res
i
st
i
ve load
Mem
o
ry
b
ack
up
:
B
acked up by Nonvolat
i
le Memory
Number of wr
i
te t
i
mes:
A
pprox. 100,000 t
i
mes
D
ata storage per
i
od:
A
pprox. 10 years
Po
w
er
:
Po
w
er s
upp
ly v
o
lta
g
e
:
85 to 264
V
A
C
(
P
ower supply
voltage range), 50/60 Hz
Rat
i
ng: 100 to 240
V
A
C
21.6 to 26.4
V
A
C
(
P
ower supply
voltage range), 50/60 Hz
Rat
i
ng: 24
V
A
C
21.6 to 26.4
V
DC
(
P
ower supply
voltage range)
Rat
i
ng: 24
V
DC
Po
w
er c
on
s
u
m
p
ti
on
:
6
VA
max. (at 100
V
A
C
)
9
VA
max. (at 240
V
A
C
)
6
VA
max. (at 24
V
A
C
)
145 m
A
max. (at 24
V
DC
)
Wei
gh
t
:
C
100:
A
pprox. 170 g
C
700:
A
pprox. 250 g
C
400/410:
A
pprox. 260 g
C
900:
A
pprox. 340 g
Alarm
ou
t
pu
t
:
Relay contact output:
250
V
A
C
, 1
A
(Res
i
st
i
ve load)
E
lectr
i
cal l
i
fe: 50,000 t
i
mes or more
(Rated load)
H
eater
b
reak alarm f
un
cti
on
:
Measured current:
0 to 30
A
(
C
TL-6-
P
-N)
0 to 100
A
(
C
TL-12-
S
56-10L-N)
Input rat
i
ng: Max
i
mum current rat
i
ng: 120 m
A
Input
i
mpedance:
A
pprox. 2.5
P
erf
o
rma
n
ce
:
D
is
p
lay acc
u
racy
(at t
h
e am
b
ie
n
t tem
p
erat
u
re 23
C
2
C
)
:
Thermocouple (T
C
):
(0.5 % of d
i
splay value
1 d
i
g
i
t) or 3
C
[6
F
]
Wh
i
chever
i
s greater
R and
S
i
nput: 0 to 399
C
[0 to 799
F
]:
6
C
[12
F
]
B
i
nput: 0 to 399
C
[0 to 799
F
]:
A
ccuracy
i
s not guaranteed.
RT
D
: (0.5 % of d
i
splay value
1 d
i
g
i
t)
or 0.8
C
[1.6
F
]
wh
i
chever
i
s greater
V
oltage/
C
urrent: (0.5 % of
i
nput span
1 d
i
g
i
t)

Other manuals for RKC INSTRUMENT REX-C100

Related product manuals