EasyManua.ls Logo

RMG EC 24 - Error Messages

RMG EC 24
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATION
...............................................................................................................................................................................................................
...............................................................................................................................................................................................................
Manual EC 24 · EN05 · 2015-02
27
Error messages
In coordinate G 01 error messages are displayed as error number followed by “Err”.
The messages no. 1 to 8 are fault messages. In this case the main totalizers stop and the disturbing
quantity totalizers start to run. The messages no. 9 to 16 are warnings and have no effect on the
totalizers.
Error no. Hexadecimal Description
1 0x0001 Parameters in EEPROM are wrong (may be wrong version)
2 0x0002 EEPROM can not be written (parameters are lost)
3 0x0004 Analog digital converter for temperature measurement
4 0x0008 Analog digital converter for pressure measurement
5 0x0010 Sensor failure
6 0x0020 Measured temperature outside limits
7 0x0040 Measured pressure outside limits
8 0x0080 Hardware and software configuration do not fit
9 0x0100 Tamper contact
10 0x0200 Error during GERG calculation
11 0x0400 Error in flow rate measurement
12 0x0800 Error in monthly data logger
13 0x1000 Current output
14 0x2000 Too many output pulses in buffer (>500)
15 0x4000 Sensor defect (check hardware)
16 0x8000 Sensor defect (check hardware)
In the column “Hexadecimal” the error bit strings displayed in coordinate Z 09 are listed.