Rhein-Nadel Automation GmbH 25
VT-BA-ESR-ESM3000-EN_2021.docx / 15 March 2021
Attention!
The settings in the Service menu described here must only be made by trained specialists as
they the function and limit values of the feeders. The supplier of the machine can decide
whether to pass on this information or reserve it for supplier’s service personnel.
This menu cannot be accessed directly in the normal menu structure, but has to be enabled via an addi-
tional key code.
The critical parameter 'output current limit' and 'vibrating amplitude range' are included in an extended Ser-
vice menu. This menu cannot be accessed directly in the normal menu structure, but has to be enabled via
an additional code number. This is to prevent unwanted changes to these critical parameters.
Current limit - Protection of the magnets against overload.
The output current limit defines the maximum permitted current for the magnets installed.
Frequency limits - Protection against system off-resonance setting.
The vibrating frequency range determines the adjustable frequency range for the user.
Output voltage limit 100 V
The output voltage limitation to operate magnets rated for 110 V on a 230 V mains supply.
Parameters:
Display
Factory default
setting:
Access
code:
Enable service menu
0 / I
En.S:
0
127
Set current limit
0...100 %
I.
100
040
Set lower frequency limit
5...300 Hz
F.L.
35
040
Set upper frequency limit
6...300 Hz
F.H.
140
040
Output voltage limitation 100 V
0 / I
P.Li.
0
040
The controller covers a maximum frequency range of 5...300 Hz. By an adjustable lower and upper fre-
quency limit, the effective frequency range for the user (parameter ‘F’) can be set to a range of max. 1.4.
Especially in the controller mode this effective frequency range is of great importance because the meas-
ured value of the acceleration sensor is safely detected. In automatic frequency search a frequency-re-
sponse ratio of 1:4 is possible. The range is limited by the frequency limits ‘F.L.’ (lower frequency limit) and
F.H. (upper frequency limit). A narrower setting of the limits than 1:4 is possible and also makes sense as it
ensures that the user setting does not deviate too much from the system frequency.
The range of the automatic frequency correction ‘AFC’ is hereby limited as well.
A limitation to +/- 20 % of the resonance frequency is a sensible setting.
1. Step: Set lower limit.
2. Step: Set upper limit.
Annex - Service
17.1. Service menu
17.2. Frequency setting range
5 Hz 300 Hz
F.L. F.H.
F.L.
F.H.
max. 1 : 4
möglicher Frequenzbereich
Parameter "F.L." und "F.H."
Menü "C 040"
nutzbarer Frequenzbereich
Parameter "F"
Menü "C 008", "C 096", C "020"
Available frequency range
Parameters ‘F.L.’ and ‘F.H.’
Menu ‘C 040’
Usable frequency range
Parameter ‘F’
Menu ‘C 008’, ‘C 096’, ‘C 020’

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RNA ESR 3000 Series and is the answer not in the manual?

RNA ESR 3000 Series Specifications

General IconGeneral
BrandRNA
ModelESR 3000 Series
CategoryController
LanguageEnglish

Related product manuals