Rhein-Nadel Automation GmbH 10
VT-BA-ESR-ESM3000-EN_2021.docx / 15 March 2021
Designation
Design
ESR 3000 / 6 A IP54
6 A, housing design with level control
ESR 3000 / 12A IP 54
12 A, housing design with level control
ESM 3000 / 6A IP20
6 A, cabinet built-in design with level control
ESM 3000 /16A IP20
16 A, cabinet built-in design with level control
For use in NFPA 79 applications only E217179
Adapters providing field wiring means are available from Rhein-Nadel Automation GmbH.
Refer to Rhein-Nadel Automation GmbH.
After tuning the controller to the vibratory feeder, the setting required by user is limited to the feed rate.
Feed rate adjustment:
Press 'P' button twice, then set feed rate with the arrow buttons (code C.000).
Parameters:
Code
Factory default
setting:
Access code:
Vibratory feeder
Vibrating amplitude (feed rate)
0...100 %
A.
0 %
000, 002
The following setting options are available to adjust the vibratory feeder
Parameters:
Display
Factory default
setting:
Access code:
Vibratory feeder
Vibrating amplitude (feed rate)
0...100 %
A.
0 %
000, 002, 020 096
Maximum control limitation (U
max
)
5...100 %
P.
90 %
008, 020, 096
Vibrating frequency
35...140 Hz
(5...300 Hz)
F.
100 Hz
008, 020
040, 096
Soft entry ramp
0...60 sec.
/.
0.1 sec.
020, 096
Soft exit ramp
0...60 sec.
\.
0.1 sec.
020, 096
Switchover to external setpoint
0 / I
E.S.P.
0
003
Setpoint 0(4)...20 mA
0 / I
4.20
0
003
Setpoint via potentiometer
0 / I
POT.
0
003
Coarse / fine control
0 / I
S.P.2.
0
003
Invert enable signal
0 / I
-En.
0
003
Indexing control
0 / I
HOP.
0
064
ON-time (with activated indexing control)
0...60 sec.
H.
1.0 sec.
004, 064
OFF time (with activated indexing control)
0...60 sec.
h.
1.0 sec.
004, 064
Hopper sensor inversion (not active)
0 / I
-Ho.
0
004, 064
Level control
ON delay
0...60 sec.
I.
1 sec.
007, 167
OFF delay
0...60 sec.
O.
1 sec.
007, 167
Invert sensor function
PNP / PNP in-
verse
-SE.
PNP
007, 167
Sensor timeout
0 / I
E.En.
0
015, 167
Time lag fault (sensor timeout)
1...240 sec.
E.
180 sec.
015, 167
Valve output stop-delay time
0...60 sec.
A.i.
4 sec.
015
Service
Show present output current
i.
040
Show present output frequency
F.
040
Save user setting
PUSH.
143
Restore factory default setting
FAC.
210
Restore user setting
US.PA.
210
Hide programming menus
0 / I
Hd.C.
0
117
Hide setpoint adjustment
0 / I
di.S.
0
137
Show software version number
001
Order designation (standard devices)
Setting options

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RNA ESR 3000 Series and is the answer not in the manual?

RNA ESR 3000 Series Specifications

General IconGeneral
BrandRNA
ModelESR 3000 Series
CategoryController