Robustel GoRugged M1000 User Guide
RT_UG_M1000 Standard_v.2.0.0 20.12.2013 31 / 83
Confidential
Modbus
Item
Description
Default
Enable
Tick to enable Modbus RTU Slave function in the modem.
Disable
Slave ID
Modbus slave ID, input from 1 to 247.
1
Coil Address
Modbus address to read coils (0x01) or wire single coil (0x05).
Input from 0 to 65535.
0
Register Address
Modus address to read holding register (0x03) or write single register
(0x05).
Input from 0 6o 65535
0
PLC Send SMS
Tick to enable.
The PLC will poll the modem to send SMS, in which the SMS content
and phone number can be set by PLC.
Disable
Send SMS Function
Code (0x05)
Read only parameters.
The function code for sending SMS.
/
Set SMS Function
Code (0x10)
Read only parameters.
The function code for setting SMS content and phone number.
/