Robustel GoRugged M1000 User Guide
RT_UG_M1000 Standard_v.2.0.0 20.12.2013 32 / 83
Confidential
The start address to save phone number, total 16 registers.
The start address to save SMS content, total 35 registers.
SMS Notification
Function Code
(0x02)
Read only parameters.
The function code for the PLC polling the modem to check whether
there is new SMS.
Read only parameters.
During polling, when there is new SMS, modem will reply 0x01.
Read only parameters.
During polling, when there is no new SMS, modem will reply 0x00.
PLC Get SMS From
Modem Function
Code (0x04):
Read only parameters.
The function code for the PLC to read new SMS and get its content.
Read Phone Number
Address
The start address to save received SMS phone number, total 10
registers.
SMS Received Date
Address
The start address to save received SMS date, total 6 registers.
SMS received
Content Address
The start address to save received SMS content, total 70 registers.
3.2.9 Coil
This tab describes Coil settings.