Rockwell Automation Publication 2198-IN016B-EN-P - October 2018 9
Kinetix 5700 DC-bus Conditioner Module
Connect Modules with Flexible Bus-bars
When the 2198-DCBUSCOND-RP312 DC-bus conditioner module is used with another
module, two flexible bus-bars make the external DC-bus lug connections to the
2198-CAPMOD-2240 capacitor module or 2198-CAPMOD-DCBUS-IO extension module.
The DC-bus links must also be installed.
Flexible Bus-bar Example
In this example, the two modules that are connected by flexible bus-bars are the DC-bus
conditioner module and extension module. However, depending on the drive system
configuration, it’s possible that any two of these modules (DC-bus conditioner, capacitor, or
extension module) could be connected and in any order.
Refer to the Kinetix 5700 Servo Drives User Manual, publication 2198-UM002, for more
information on drive system configurations.
ATTENTION: To avoid damage to components on 208 A systems, the DC-bus links and the flexible
bus-bars must be installed.
24V–
24V+
24V–
24V+
19
8
16
SB+/NC
NC
S1A
SCA
S2A
SB-
NC
NC
2198-DCBUSCOND-RP312
DC-bus Conditioner Module
Flexible bus-bars
(external DC-bus connections)
2198-CAPMOD-DCBUS-IO
Extension Module
DC-bus Link Connections
2198-xxxx-ERSx
Inverters
DC-bus Links