Publication 2711P-UM001D-EN-P - September 2005
5-18 Install and Replace Components
For PanelView Plus 1250 and 1500
The 1250 Series A and B displays have two backlights and use
cat. no. 2711P-RL12C backlight replacement.
The 1250 Series C displays have only one backlight and use
cat. no. 2711P-RL12C2 backlight replacement.
The 1500 Series B displays have four backlights and use cat. no.
2711P-RL15C backlight replacement.
Work on a clean, flat, stable surface to protect the display from
debris, scratches and damage.
8. Remove the screw(s) that secure the backlight(s) and remove
the backlight(s).
The two backlights for the 1250 Series A and B displays are
each secured with two screws.
The single backlight for the 1250 Series C displays is secured
with one screw.
For the 1500 Series B displays, remove the tape and then
remove the backlights.
9. Insert the new backlight(s) and secure with the same screws.
Torque the screws to 0.117 Nm (1.04 in-lb).