Rockwell Automation Publication 520-UM001I-EN-E - July 2016 145
Programming and Parameters Chapter 3
Fault and Diagnostic Group (continued)
F683 [Com Sts-Emb Enet]
PowerFlex 525 only.
Displays the status of the embedded EtherNet/IP interface to the drive.
Values Default: Read Only
Min/Max: 0000/1911
Display: 0000
PF 525
1 = Condition True, 0 = Condition False
Rx Digit 1
Tx Digit 2
Status Digit 3
Error Digit 4
Not Used
Digit 3 = “Embedded EtherNet/IP”
0 Not Active (no connection)”
1 “Embedded EtherNet/IP active”
2-8 “Reserved”
9 “Embedded EtherNet/IP faulted”
F684 [EN Addr Src]
PowerFlex 525 only.
Displays the actual source of the Ethernet configuration (IP address, subnet mask, and gateway address).
Options 1 “Parameters” Read Only
2“BOOTP
PF 525
F685 [EN Rate Act]
PowerFlex 525 only.
Displays the network data rate currently used by the embedded EtherNet/IP interface.
Options 0 “No Link” Read Only
1 “10Mbps Full”
2 “10Mbps Half
3 “100Mbps Full”
4 “100Mbps Half
5 “Dup IP Addr”
6“Disabled
PF 525
F686 [DSI I/O Act]
Displays the Drives that are active in Multi-Drive mode.
Value Default: Read Only
Min/Max: 00000/11111
Display: 00000
1 = Drive Active, 0 = Drive Inactive
Drive 0 Actv Digit 1
Drive 1 Actv Digit 2
Drive 2 Actv Digit 3
Drive 3 Actv Digit 4
Drive 4 Actv Digit 5