148 Rockwell Automation Publication 520-UM001I-EN-E - July 2016
Chapter 3 Programming and Parameters
Fault and Diagnostic Group (continued)
F708 [Drv 0 Feedback]
F712 [Drv 1 Feedback]
F716 [Drv 2 Feedback]
F720 [Drv 3 Feedback]
F724 [Drv 4 Feedback]
In multi-drive mode, this is the feedback being received from drive 0/1/2/3/4.
In single-drive mode, this is the feedback of the drive at the time.
Values Default: Read Only
Min/Max: 0.00/500.00 Hz
Display: 0.01 Hz
F725 [EN Rx Overruns]
PowerFlex 525 only.
A count of the number of receive overrun errors reported by the embedded EtherNet/IP interface.
Values Default: Read Only
Min/Max: 0/65535
Display: 1
PF 525
F726 [EN Rx Packets]
PowerFlex 525 only.
A count of the number of receive packets reported by the embedded EtherNet/IP interface.
Values Default: Read Only
Min/Max: 0/65535
Display: 1
PF 525
F727 [EN Rx Errors]
PowerFlex 525 only.
A count of the number of receive errors reported by the embedded EtherNet/IP interface.
Values Default: Read Only
Min/Max: 0/65535
Display: 1
PF 525
F728 [EN Tx Packets]
PowerFlex 525 only.
A count of the number of transmitted packets reported by the embedded EtherNet/IP interface.
Values Default: Read Only
Min/Max: 0/65535
Display: 1
PF 525
F729 [EN Tx Errors]
PowerFlex 525 only.
A count of the number of transmit errors reported by the embedded EtherNet/IP interface.
Values Default: Read Only
Min/Max: 0/65535
Display: 1
PF 525