Rockwell Automation Publication 520-UM001I-EN-E - July 2016 81
Programming and Parameters Chapter 3
Basic Display Group (continued)
b018 [Power Saved] Related Parameter(s): b017
Instantaneous power savings of using this drive compared to an across the line starter.
Values Default: Read Only
Min/Max: 0.00/655.35 kW
Display: 0.01 kW
b019 [Elapsed Run time] Related Parameter(s): A555
Accumulated time drive is outputting power. Time is displayed in 10 hour increments.
Values Default: Read Only
Min/Max: 0/65535 x 10 hr
Display: 1 = 10 hr
b020 [Average Power] Related Parameter(s): A555
Average power used by the motor since the last reset of the meters.
Values Default: Read Only
Min/Max: 0.00/(Drive Rated Power x 2)
Display: 0.01 kW
b021 [Elapsed kWh] Related Parameter(s): b022
Accumulated output energy of the drive. When the maximum value of this parameter is reached, it resets to zero and b022 [Elapsed MWh] is incremented.
Values Default: Read Only
Min/Max: 0.0/100.0 kWh
Display: 0.1 kWh
b022 [Elapsed MWh] Related Parameter(s): b021
Accumulated output energy of the drive.
Values Default: Read Only
Min/Max: 0.0/6553.5 MWh
Display: 0.1 MWh
b023 [Energy Saved] Related Parameter(s): A555
Total energy savings of using this drive compared to an across the line starter since the last reset of the meters.
Values Default: Read Only
Min/Max: 0.0/6553.5 kWh
Display: 0.1 kWh
b024 [Accum kWh Sav] Related Parameter(s): b025
Total approximate accumulated energy savings of the drive compared to using an across the line starter.
Values Default: Read Only
Min/Max: 0.0/6553.5 kWh
Display: 0.1 = 10 kWh