15 Safety input and command status (TEST mode)
;MXLRSGYVVIRXP]EGXMZIGSQQERHWTVIWWXLI8)78FYXXSRERHGLIGOXLIJSPPS[MRK
DISPLAY POSSIBLE CAUSE ACTION BY SOFTWARE PHYSICAL CORRECTIVE ACTION
 6E(Sb)
The release handle is open.
-
Close the release handle and turn the
key to the close position.
Check that the release contact is con-
nected correctly.

The safety STOP contact is open.
-
Install a STOP button (NC) or jumper
the ST contact with the COM contact.

Sensing edge COS1 not connect-
ed or incorrectly connected.
Set the parameter   if not
used or to disable
Jumper contact COS1 with contact
COMMJRSXYWIHSVXSHMWEFPI

Sensing edge COS2 not connect-
ed or incorrectly connected.
Set the parameter   if not
used or to disable
Jumper contact COS2 with contact
COMMJRSXYWIHSVXSHMWEFPI

Photocell FT1 not connected or
incorrectly connected.
Set the parameter  e 
if not used or to disable
Jumper contact FT1 with contact COM
if not used or to disable. Check con-
nection referring to relative connection
HMEKVEQƼK

Photocell FT2 not connected or
incorrectly connected.
Set the parameter  e 
if not used or to disable
Jumper contact FT2 with contact COM
if not used or to disable. Check con-
nection referring to relative connection
HMEKVEQƼK
 )(
Both limit switches in open con-
tact state or not connected.
-
Check connection of limit switches.
 )$
Gate is at gate closed limit switch. If the limit switch state indicated is
MRGSVVIGXGLIGOXLIWIXXMRKSJTEVE-
meter .
-
Gate open limit switch absent or
not connected.
-
Check connection of limit switches.
 )&
Gate is at gate closed limit switch. If the limit switch state indicated is
MRGSVVIGXGLIGOXLIWIXXMRKSJTEVE-
meter .
-
Gate closed limit switch absent or
not connected.
-
Check connection of limit switches.
SS 
If occurs with no voluntary com-
QERH XLI GSRXEGX 23 QE] FI
faulty or one of the buttons may be
incorrectly connected.
-
Check PP - COM contacts and connec-
tions to buttons.
&+ 
-
Check CH - COM contacts and connec-
tions to buttons.
DS 
-
Check AP - COM contacts and connec-
tions to buttons.
SH 
-
Check PED - COM contacts and connec-
tions to buttons.
2U
If occurs with no voluntary com-
QERH XLI GSRXEGX 23 QE] FI
faulty or the timer may be incor-
rectly connected.
-
Check ORO - COM contacts. Contact
must not be jumpered if not used.
N.B. Press TEST button to exit from the TEST Mode.