Program module "Terminal" R&S NRP-Z91
1168.8579.12 3.4 E-1
Filtering is started with Apply.
The number of lines matching the filter
criterion is displayed in the Linecounter field. If Open on startup
is
active, the Output Postfilter
dialog is automatically opened when the
terminal is started. The dialog window is closed with OK.
.
Response
Time …
Opens the Response time
dialog window where the response time of
the sensor can be set.
Current
indicates the time elapsed between dispatch of the last
command and receipt of an acknowledgement from the sensor.
When the Max
button is clicked, the response times exceeding the
value in the limit / ms field are recorded. When the Min
button is
clicked, the response times within the value in the limit / ms
field are
recorded.
If Trigger on first incoming response
is active, the time
measurement is terminated as soon as the first response arrives after a
command is sent. If Trigger on response matching filter settings
is
active, the time measurement is terminated as soon as the first
response matching the filter criterion in the Output Postfilter
dialog
window is received.
If Open on startup is active, the Response Time dial
og is
automatically displayed when the Terminal module is started.
The
dialog window is closed with OK.
Loop … Opens the Loop controls dialog
window where the cyclic transfer of
commands and command sequences
can be controlled.
In the Delay / ms field, the time
interval for the cyclic transfer is
specified in milliseconds.
The number of completed transfer
cycles is displayed in the Counter
field. If Open on startup
is active, the
Response time dialog is
automatically opened when the
Terminal module is started.
The dialog
window is closed with OK.