Remote Control Commands
R&S
®
SMA100B
433User Manual 1178.3834.02 ─ 05
The dialog ID is also required to define user key actions.
See Chapter 11.2.3, "Assigning Actions to the [★ (User)] Key", on page 326.
// Query the dialog IDs of all open dialogs
:DISPlay:DIALog:ID?
// CEUtraDLGenSetDlg,_,$A DlgKeyRf_Rosc
// Open and close dialogs via remote control
:DISPlay:DIALog:OPEN "CEUtraDLGenSetDlg,_,$A"
:DISPlay:DIALog:OPEN "DlgKeyRf_Rosc"
:DISPlay:DIALog:CLOSe "DlgKeyRf_Rosc"
:DISPlay:DIALog:CLOSe:ALL
:DISPlay:PSAVe:HOLDoff............................................................................................... 433
:DISPlay:PSAVe[:STATe].................................................................................................433
:DISPlay:BRIGhtness..................................................................................................... 434
:DISPlay:BUTTon:BRIGhtness.........................................................................................434
:DISPlay:UPDate........................................................................................................... 434
:DISPlay:ANNotation:AMPLitude..................................................................................... 434
:DISPlay:ANNotation:FREQuency....................................................................................435
:DISPlay:ANNotation[:ALL]..............................................................................................435
:DISPlay:DIALog:ID?......................................................................................................435
:DISPlay:DIALog:OPEN..................................................................................................436
:DISPlay:DIALog:CLOSe................................................................................................ 436
:DISPlay:DIALog:CLOSe:ALL..........................................................................................437
:DISPlay:PSAVe:HOLDoff <HoldoffTimeMin>
Sets the wait time for the screen saver mode of the display.
Parameters:
<HoldoffTimeMin> integer
Range: 1 to 60
*RST: n.a. (factory preset: 10)
Default unit: minute
Example: see Example "Activating screen saver mode and display update"
on page 432
Manual operation: See "Wait Time" on page 319
:DISPlay:PSAVe[:STATe] <State>
Activates the screen saver mode of the display.
We recommend that you use this mode to protect the display, if you operate the instru-
ment in remote control.
To define the wait time, use the command :DISPlay:PSAVe:HOLDoff.