What to do if Rohde & Schwarz Portable Generator shows overload?
A
Andrew LeeAug 20, 2025
If the Rohde & Schwarz Portable Generator indicates an overload, reset the overload protection by pressing the RF ON/OFF key. The RF input is activated once the overload protection is reset.
T
Todd PachecoAug 21, 2025
What to do if Rohde & Schwarz Portable Generator cannot access hardware?
M
Maria HernandezAug 21, 2025
If the Rohde & Schwarz Portable Generator cannot access the hardware, it means the data transmission to a module was unsuccessful. The module might not be installed, improperly installed, or missing. Ensure the module is correctly installed.
M
michael64Aug 25, 2025
What to do if Rohde & Schwarz Portable Generator adjustment failed?
M
Michael JohnsonAug 25, 2025
If the adjustment failed on the Rohde & Schwarz Portable Generator, the adjustment data have to be generated first by an internal or external adjustment or to be loaded into the device.
L
Laurie FloresAug 26, 2025
Why Rohde & Schwarz Portable Generator says external reference out of range?
L
ljoyceAug 26, 2025
The Rohde & Schwarz Portable Generator displays 'External reference out of range' because an external reference is selected, but either no external signal is applied or the signal is out of range. To resolve this:
* Check the selected reference signal source (internal or external) in the 'Setup > Reference Oscillator' dialog.
* Change the setting to 'internal' if no appropriate external source is available.
C
cmayAug 27, 2025
What to do if Rohde & Schwarz Portable Generator says adjustment data missing?
C
Craig WilsonAug 27, 2025
If the Rohde & Schwarz Portable Generator indicates that adjustment data is missing, the adjustment data have to be generated first by an internal or external adjustment or to be loaded into the instrument.
D
David BrooksAug 29, 2025
What does it mean if Rohde & Schwarz Portable Generator says hardware revision out of date?
S
Samuel GlassAug 29, 2025
If the Rohde & Schwarz Portable Generator displays 'Hardware revision out of date', it means a later version of certain parts of the instrument is necessary to execute the function selected. The driver does not support the installed version of a module.
J
jweaverAug 31, 2025
What to do if Rohde & Schwarz Portable Generator says adjustment data invalid?
M
Mrs. April Martinez MDSep 1, 2025
If the Rohde & Schwarz Portable Generator reports that the adjustment data is invalid, the adjustment data have to be generated again by an internal or external adjustment or to be loaded into the instrument.
E
elliottmatthewSep 3, 2025
What to do if Rohde & Schwarz Portable Generator cannot access the EEPROM?
J
Joseph WilliamsSep 3, 2025
If the Rohde & Schwarz Portable Generator cannot access the EEPROM, it's because an error occurred when writing or reading a EEPROM. The EEPROM might be defect and has to be replaced.
L
Leslie TaylorSep 5, 2025
What to do if Rohde & Schwarz Portable Generator says no current list?
E
Eric HartSep 5, 2025
If the Rohde & Schwarz Portable Generator indicates 'No current list', it means that there is no list selected. If no list is available, a new list must be created.
V
vmoranSep 6, 2025
What to do if Rohde & Schwarz Portable Generator cannot open file?
J
joycewaltonSep 6, 2025
If the Rohde & Schwarz Portable Generator cannot open a file, check the path and file name to ensure they are correct.
Introduces the general concept of the R&S SMC, explaining its operating concept and three ways of instrument control: manual, remote control, and remote access.
Describes the application fields of the R&S SMC, highlighting its suitability for sine wave signals with high spectral purity and its adjustable frequency range.
Describes the instrument's display, showing main settings and signal generator states, divided into sections like frequency/level display and block diagram.