EasyManua.ls Logo

Rohde & Schwarz SMC100A - [:Source<Hw>]:Sweep[:Frequency]:Running; [:Source<Hw>]:Sweep[:Frequency]:Shape; [:Source<Hw>]:Sweep[:Frequency]:Spacing

Rohde & Schwarz SMC100A
413 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMC100A
336Operating Manual 1411.4060.32 ─ 09
[:SOURce<hw>]:SWEep[:FREQuency]:RUNNing?
Queries the current state of the frequency sweep mode.
Return values:
<State> 0 | 1 | OFF | ON
Example:
SWE:RUNN?
Response "1": signal generation in level sweep active.
Usage: Query only
[:SOURce<hw>]:SWEep[:FREQuency]:SHAPe <Shape>
Sets the cycle mode for a sweep sequence (shape).
Parameters:
<Shape> SAWTooth | TRIangle
SAWTooth
One sweep runs from start to stop frequency. Each subsequent
sweep starts at the start frequency, i.e. the shape of the sweep
sequence resembles a sawtooth.
TRIangle
One sweep runs from start to stop frequency and back, i.e. the
shape of the sweep resembles a triangle. Each subsequent
sweep starts at the start frequency.
*RST: SAWTooth
Example:
SOUR:SWE:SHAP TRI
selects the sweep cycle with alternating ascending and
descending sweep directions.
Manual operation: See " Shape - RF Frequency Sweep " on page 161
[:SOURce<hw>]:SWEep[:FREQuency]:SPACing <Spacing>
Selects the mode for the calculation of the frequency sweep intervals. The frequency
increases or decreases by this value at each step.
The keyword [:FREQuency] can be omitted. Then the command is SCPI-compliant.
SOURce Subsystem

Table of Contents

Other manuals for Rohde & Schwarz SMC100A

Related product manuals